CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean filter,
fan and grease-laden surfaces. Use only a clean cloth and mild
detergent solution on stainless and painted surfaces. Clean all-
metal filters in the dishwasher.
The motor is permanently lubricated and never needs oiling. If
the motor bearings make excessive or unusual noise, replace
the motor with the exact service motor. The impeller should also
be replaced.
Use 120 V, 50 W, shielded halogen bulbs - MR16 or PAR16 with
GUI0 base. Purchase bulbs separately.
The grease filters, bottom panel, and blower wheel should be
cleaned frequently. Use a warm detergent solution. The grease
filters and blower wheel are dishwasher safe.
Note: Some minerals, when in contact with dishwasher
soap additives, may cause filters to discolor. This discol-
oration is not covered by the warranty.
AP SERIES HOOD
Operate the hood as follows:
©
®
e
o
FAN
0
LIGHT
FAN
The 2-position switch (in center) turns blower ON and OFF.
The 5-position switch (at left) controls blower speed.
O Blower is OFF (secondary blower OFF).
Blower is ON at highest speed.
® As dots get smaller - blower speed decreases.
O
OPERATION
Always turn the hood ON before cooking in order to establish an
air flow in the kitchen. After turning off the range, let the hood run
for a few minutes to clear the air.
HEAT SENTRY TM
The hood is equipped with a Heat Sentry TM thermostat. This safety
device wilt turn on or speed up the blower if it senses excess heat
above the cooking surface.
If the blower is not on, or if it is running at tow speed, the Heat
Senttry TM will override the normal blower control and trun the
blower on the high speed. When the temperature level drops to
normal levels, the blower will return to its original setting.
RP SERIES HOOD
Operate the hood as follows:
J
_ BLOWER SWITCH
This 3-position switch turns blower ON and OFF and controls
blower speed.
Set switch to (1) position to turn blower ON to tow speed.
Set switch to (2) position to turn blower ON to high speed.
Set switch to (0) position to turn blower OFF.
"_ LIGHT SWITCH
This 3-position switch turns lights ON and OFF and controls
their intensity.
Set switch to (1) position to turn lights ON to tow intensity.
Set switch to (2) position to turn lights ON to high intensity.
Set switch to (0) position to turn lights OFF.
LIGHT
This 3-position switch (at right) turns lights ON and OFF and
controls their intensity.
O Lights are OFF.
(_ Lights are ON to low intensity.
Lights are ON to highest intensity.
PREPARE HOOD LOCATION
ROOF CAP
3%"X 10"
(For vertical
SOFFIT
HOUSE WIRING
or Back of hood)
WALL CAP
A 3¼" X 10" DUCT
|
(For horizontal discharge
18" - 24" ABOVE
COOKING SURFACE
E3
Determine whether hood will discharge vertically or hori-
zontally. For vertical or horizontal discharge, run ductwork
between the hood location and a roof cap or wall cap. For
best results, use a minimum number of transitions and
elbows.