PREPARATION
Follow these steps to ensure accurate measurements:
Seal all the ductwork with tape. Close all windows and doors.
Turn off all exhaust devices such as range hood, dryer and bathroom fans.
If the installation is in any way connected to a ductwork of a central forced-air system, make sure that the central forced-air system
blower is ON. If not, leave central forced-air system blower OFF.
AUTO-BALANCING PROCEDURE
1. Plug the unit and wait for the maximum CFM to display on the LCD screen. At fi rst
boot, it will take longer to get the information since motors have to preheat.
2. The maximum CFM will display on the LCD screen. Use (+/-) to adjust the CFM and
OK to confi rm.
3. The minimum CFM will display on the LCD screen. Use (+/-) to adjust the CFM and
OK to confi rm.
4. INS will display on the LCD screen. Choose among T-1, T-2, T-3, T-4 or T-5 following the
installation confi guration (Refer to section 2.2 for more details).
5. If required, options can be confi gured. While on CFG OPT screen, press on the OK button for 4 seconds. Use (+/-) to change the
confi guration and OK to confi rm. If not required, press OK to skip this menu.
Options Con gurations available
DEF (Defrost) DIS* (Discretion - defrost without speed variation for more comfort),
PLU (Plus - extended defrost for colder areas)
INS (Installation) T-1, T-2, T-3, T-4*, T-5 (Refer to section 2.2)
DRY (Dry contact) MIN* (Minimum), INT (Intermittent), AUT (AUTO), MAX (Maximum) (Refer to section 3.3.1)
OVR (Override) BAL* (Balanced), PER (Performance), DIS (Discretion) (Refer to section 3.2.1)
INT (Intermittent) STB* (Standby - 20 min in MIN speed and 40 min in standby mode), REC** (Recirculation - 20 min in MIN
speed and 40 min in recirculation mode)
6. Auto-balancing is completed.
5. UNIT AUTO-BALANCING
+
-
OK
VD0492
If any change is made to the ducting, reset settings to restart the airfl ow test.
PROCEDURE TO RESET SETTINGS
Press on the OK and (-) buttons simultaneously for 4 seconds. Use (+/-) to select Yes or No and OK to confi rm.
Then perform the auto-balancing procedure.
6. USING THIS UNIT
This balanced ventilation unit is designed to provide fresh air to your home while exhausting stale, humid air. Thanks to its energy/heat
recovery module, the unit recovers a large proportion of heat or energy that is part of indoor or outdoor air according to the seasons to
improve comfort and energy effi ciency during the heating and the cooling periods. With the Virtuo Air Technology
TM
, this unit responds
to the variations in its environment in an autonomous way, ensuring to provide a proper level of ventilation and air quality. This unit also
features automatic modes (AUTO or SMART) that manage autonomously the required ventilation level as per indoor and/or outdoor
conditions. In colder areas, the unit will perform, at intervals, recovery module discreet defrost to maintain performance and comfort.
6.1 YOUR VENTILATION SYSTEM
6.2 INTEGRATED CONTROL
All units are equipped with an integrated control, located in front of the electrical compartment. For more convenience, these units can
be controlled using an optional wall control or the central forced-air system thermostat equipped with external fan activation.
+
-
OK
VD0492
MODE SELECTION
1. To change the mode, use (+/-) to access the Mode screen. Press OK to edit the mode
and use (+/-) to change the mode (Standby, Min, Max).
2. Press OK to confi rm selection. The airfl ows will be displayed for both MIN and MAX
modes.
NOTE: If an optional auxiliary wall control or the central forced-air system thermostat
equipped with external fan activation is used, it overrides the integrated control.
** REC (Recirculation) confi guration is not available for 150H75NT, 150H75NS, 150E75NT and 150E75NS units.
NOTE: If no selection is confi rmed within 10 minutes, the unit will exit the menu without saving any changes.
NOTE: If speed or confi guration need to be modifi ed, go to MIN, MAX or CFG using (+/-), then press on the OK button for 4 seconds.
Use (+/-) to increase/decrease speed and OK to confi rm.
* Factory setting