User Guide

21
1. Repeat steps 1 to 6 from the previous section and continue with the following steps:
2. Clean the recovery core:
HRV MODELS ERV MODELS
Remove the core.
Let it soak in a mixture of cold or lukewarm water and mild
soap (dishwashing liquid).
• Rinse thoroughly.
Shake the core to remove excess water and let it dry.
Remove the dust on the core using a vacuum cleaner and a
soft brush attachment.
CAUTION: DO NOT SOAK THE ENERGY RECOVERY
CORE IN WATER
3. Clean the blower assemblies. Do not disassemble the blower assemblies.
4. Remove the dust using a vacuum cleaner with a soft brush attachment.
5. Reassemble the components.
6. Reconnect power supply.
CAUTION
Handle the recovery core with care.
PROBLEM TRY THIS
1. Nothing works. See if the unit is plugged in.
See if the unit is receiving power from the house circuit breaker or fuse.
2. Noisy unit. Clean the unit (see Section 9). If the problem is not solved, contact your installer.
3. Condensation inside windows under
cold weather conditions.
Operate the unit at MAX speed during activities generating excess humidity (family
gatherings, extra cooking, etc.).
Leave curtains half-open to allow air circulation.
Store all fi rewood in a closed room with a dehumidifi er or in a well ventilated room, or
store the wood outdoors.
Keep the temperature in your house above 64°F.
4. Humidity inside under hot/humid
weather conditions.
Operate the unit in MIN speed.
Temporarily switch to INT mode (if available).
Use a dehumidifi er.
5. Air too dry. Operate the unit at MIN speed.
Temporarily switch to INT mode (if available).
Temporarily use a humidifi er.
6. Air too cold at the air supply register. Make sure the outdoor hoods are not blocked.
Operate the unit at MIN speed.
Install a duct heater (contact your installer).
9.2 ANNUAL (AT FALL)
10. USER’S TROUBLESHOOTING
Contact customer service at 1-800-558-1711 for any unresolved issue.
VD0494
9. MAINTENANCE (CONTD)