Manual

SR - N
MODELS B5630SS ,, B5636SS ,, B5730SS ,, B5736SS
Page 6
6"ROUND
STEEL DUCT
I
DUCT LENGTH
DECORATIVE
FLUE
8. Measure and install steel ductwork to hood duct connector.
Use duct tape to make all joints secure and air tight.
9. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
10.Align the hood and center it above the hood mounting
bracket. Make sure ductwork on hood lines up and attaches
to ductwork in ceiling. Gently lower the hood until it securely
engages the bracket.
11. Use duct tape to make all joints secure and air tight.
i
i
I
i
I
i
I
SDE VEW
.............. I
INSIDE BACK
OF THE HOOD
MOTOR/BLOWER
ASSEMBLY
/
HOLES LOCATION
12.With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5/16" drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) #8 x 1-1/2"
mounting screws through the hood back and into the drywall
anchors. Verify that the hood is centered and leveled. Tighten
all screws completely.
13. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Pull down the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.
14. Slightly push aside the upper flue to avoid any damage while
installing the lower flue to the hood top using (2) #8 x 3/8"
screws through the lower flue side slots.
UPPER FLUE MOUNTING BRACKET
I
UPPER _ _
FLUE / F
15. Slide the upper flue upward until it is aligned with its mounting
bracket. The bracket should be inside the flue. Secure the
upper flue to the upper flue mounting bracket using (2)
#8 x 3/8" mounting screws.
16. Remove protective plastic film covering the upper flue and
the hood.
17.
Mount the glass plate or the stainless steel plate to the top
of hood base with (4) flat head screws (M4 x 1.0") and (4)
decorative washers. Screw from top of hood base. Do not
overtighten these screws.
INSTALL THE HOOD
(Non-Ducted Hoods Only)
NON=DUCT KIT MODEL RK56 CONTENTS
NON-DUCTED _
RECIRCULATION
FILTERS
NON-DUCT
PLENUM
NON-DUCT PLENUM
COLLAR
8 MOUNTING
SCREWS (_
(ST4 x 8
Round Head)
WRAPS "_% FLEXIBLE DUCT
NOTE: Non=ducted installations require Non=Duct Kit, Model
RK56 (purchase separately).
1. CAUTION: Do not use plastic or rigid metal duct.
2. Do not remove the protective plastic film covering the decorative
flue and the hood at this time.
3. Lay the back side of the hood flat on a table. Use a piece of
cardboard to avoid damaging the table or the hood.
4. Attach damper / duct connector to top of hood using (4)
#8 x 3/8" Pan Head mounting screws.
5. Remove damper flaps from damper / duct connector and
discard flaps.