Spec Sheet
HEAT RECOVERY VENTILATOR AND
ENERGY RECOVERY VENTILATOR
FOR LIGHT COMMERCIAL APPLICATIONS
High CFM ventilation for small business owners concerned about
indoor air quality (excess moisture, smoke, odors and cleanliness).
Suitable for installation above a suspended ceiling, mechanical room
or suspended from a ceiling, this model delivers year-round comfort
and sensible heat recovery with virtually no cross leakage. On this unit,
the heat exchange efficiency can reach up to 66%.
• Only 24.5” high for false ceiling installation
• Defrost system
• Two-speed control
• Low voltage remote switch
REPAIRS AND MAINTENANCE
All parts of the B6LC such as the large access door and the entire motor
sub-assembly can be removed for ease of maintenance. Furthermore,
the electronic circuit board reduces electro-mechanical parts,
minimizing repair time.
ORDERING EXAMPLE
B6LC
VB0240
Available at:
Control
• Built-in electronic circuit board ready to receive the VT1W main
wall control.
Heat Recovery Cores/Energy Recovery Cores
Dimensions: 12” x 12” x 13.125”
Exchange surface: 200 ft²
Weight: HRV Polypropylene: 9.2 lb. ; Aluminum: 13.9 lb.
ERV Polymerised paper: 11.2 lb.
Type: Plate to plate core
Quantity: 2
Material: HRV polypropylene or aluminum
ERV polymerised paper
Warranty: HRV 15 years; ERV 5 years
VK0103A
15"
[381]
CORE
REVERSED DOOR OPTION
A MINIMUM OF 15" [381] CLEARANCE FROM ANY OBSTRUCTION IS REQUIRED
FOR REMOVAL OF CORES, FANS, ETC.
THE ACCESS DOOR CAN BE REMOVED FROM CABINET
WITH ONLY 2" [51] OF CLEARANCE.
ACCESS DOOR
Option
• Medium eciency air supply lters
Recirculation or exhaust defrost
Requirements and standards
• Complies with the CSA C22.2, no. 113 Standard applicable to ventilators
• Complies with UL Standard 1812 - ducted Heat Recovery Ventilators
or Energy Recovery Cores
Warranty
The B6LC unit is fully protected by a 2-year warranty on parts, the best
in the industry, and the heat recovery cores are covered by a 15-year
warranty.
FROST CONTROL
D Recirculation defrost
E Exhaust only
CORE MATERIAL
P
Polypropylene
core
A Aluminum core
H Polymerised
paper ERV HM
ACCESS DOOR
S Standard door
R
Reverse door
(right hand ow)
LOW SPEED
N Normal low speed
When ordered‚ the recirculation defrost damper module is factory
installed.
BROAN B6LC
Part no. B6LC
560 to 690 CFM (0.4 in. w.g.)
N
OutdOOr temperature defrOst cycle (in minutes)
°C °F
defrOst/OperatiOn
Warmer than -5 Warmer than 23 no defrost
-5 to -15 23 to 5 12/60
-15 to -30 5 to -21 12/24
-30 & less -21 & less 12/12