WWW.BROAN.COM WWW.BROAN.CA WWW.NUTONE.
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 Cleaning and Maintenance . . . . . . . . . . . . . . . . . 7 Motors Grease Filters Non-Ducted Recirculation Filters Fan Wheels Stainless Steel Cleaning Painted Finish Cleaning Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20 INSTALLATION MANUAL TABLE OF CONTENTS Recommended Tools and Accessories for Installation . . . . . . . . .
READ AND SAVE THESE INSTRUCTIONS ! Intended for domestic cooking only ! INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. In U.S.A., register your range hood online at www.broan.com In Canada, register your Broan range hood online at www.broan.ca or register your NuTone range hood online at www.nutone.ca ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Use this unit only in the manner intended by the manufacturer.
! WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fan frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts. d) Use proper pan size.
Operation Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows: 1 NOTE: At range hood start-up or after a power failure, a small icon (1) appears shortly (for ± 2 seconds) on LCD screen; this is normal.
DELAY OFF When the blower is on, press this button to activate the delay function. This icon appears on LCD screen beside the blower icon to indicate the function is on. The blower will continue to operate for 10 minutes and then, will shut off automatically (both blower and delay icons will disappear from LCD screen). When Delay off is activated, it is possible to change the blower speed by pressing on blower push button without affecting the remaining time of the delay.
Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTORS The motors are permanently lubricated and never need oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan wheel should also be replaced. GREASE FILTERS The grease filters should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe.
For ADA compliance installation guidelines, please visit www.broan-nutone.com Recommended Tools and Accessories for Installation • • • • • • • • • • • • • • • Measuring tape Phillips screwdriver no.
Contents Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: * FIND INSIDE OF HOOD (1) 3¼” X 10” DAMPER ASSEMBLY* (2) GREASE FILTERS (1) 7” ROUND DUCT CONNECTOR EZ1 COMPONENTS Use this template for marking; do not attempt to cut out the ducting hole through it. NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
Prepare the Hood 1 ] If present, remove all protective polyfilm from the hood and/or parts. 2 ] Remove 7” Round Duct Plate from top/back of hood (see illustration below). Keep the screws for further use. 7” ROUND DUCT PLATE 2 SCREWS 3 ] Using the finger cup, remove the grease filters from the hood by pushing down and tilting filters out .
5 ] Remove the damper assembly, taped over the EZ-1 brackets, and the parts bag, taped on the inner back of hood, near the left corner. DAMPER ASSEMBLY PARTS BAG LOCATION NOTE: The damper assembly has to be slightly bent to fit inside the range hood. Once removed, bent it back to ensure its opening is rectangular (4 corners at 90°). 6 ] Remove the EZ1 brackets from inside the hood by cutting off the tie wrap.
DUCTED INSTALLATION ONLY 8 ] Remove 3¼” x 10” vertical or 3¼” x 10” horizontal (both are the rectangular central knockout plates, see hatched areas) or 7-inch round knockout plate as appropriate for your ducting method (see FIGURES 1 A and 1 B).
Prepare the Hood Location This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). For the standard installation, go to page 18. EZ1 one-person installation system EZ1 installation is designed for use with kitchen cabinets that have the same width designation as the range hood width. If the cabinet is greater than 1/2” wider than the range hood width, please use the standard installation method.
6 ] Install the proper installation brackets according to the type of cabinet (framed or frameless). See below. FRAMED CABINET Refer to the marking on brackets to determine the correct installation side and orientation. 7/64” INSTALLATION MANUAL INSTALLATION 14 Mate the corresponding bracket to the cabinet side frame, while placing rear end of bracket against the wall. Use a pencil to mark 3 holes (there are 6 holes but only 3 are necessary). Remove the bracket.
FRAMELESS CABINET Refer to the marking on brackets to determine the correct installation side and orientation. 3X 7/64” against the wall. Draw a line on the outer edge of the bracket (as shown). keeping the rear end edge leaning on the wall. Use a pencil to mark 3 holes. Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked. Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws.
Install the Hood (EZ1 Bracket) NOTE: The following procedure applies to both frame or frameless cabinet installations. 1 ] Run house power cable between service panel and hood location. 2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below); these holes allow the range hood to hang on the brackets (previously installed).
7 ] For framed cabinet, secure the hood to the EZ1 brackets using four (4) no. 8-18 x 1/2” metal screws with washers. For frameless cabinet, secure the hood to the cabinet using four (4) no. 8 x 5/8” round head wood screws (screws and washers included in parts bag). Insert two (2) screws and washers per side, in the slots (as shown in insets on illustration below).
Standard Installation (without EZ1 brackets) 1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
Install the Hood (Standard Installation) NOTE: Two installers are recommended because of the weight of this hood. 1 ] Run house power cable between service panel and hood location. For hood with power cable access located on back of hood, run the house power cable into the hood through the strain relief previously installed in step 7 on page 11. For hood with power cable access located on top, tighten the strain relief to the power cable before inserting the strain relief in the knockout hole.
Connect the Wiring ! WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. MOTORS GROUND WIRE GROUND SCREW HOUSE POWER CABLE 1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
BK W INSTALLATION MANUAL LCD INTERFACE 1 2 3 4 5 1 2 3 4 5 6 7 WIRING DIAGRAM Ground Neutral Line J8 Control Board J4 LED J6 Override J1 Transformer 1 2 3 4 1 2 3 4 5 6 J2 Power, Motor 5 4 3 2 1 120 V AC BL BK R G/Y BK PP R (Low) O (Medium) BK (High) W BL R BK R Fuse 5 A W BK W W 1 2 3 4 5 1 2 3 4 5 W LED LED W PP BK O 120 BL 88 PP 60 PN 45 Y 10 W W G/Y PP BK BL BN BN/S G/Y O G/Y 6 5 4 3 2 1 6 5 4 3 2 1 W O BK G/Y R FAN MOTOR W O BK G/Y R FAN MOTOR PN PP
BCDJ AND NCDJ SERIES C B O D N E F G M L K H H J I KEY NO. 2 3 4 5 6 7 8 9 10 11 12 13 14 * S97020029 S97020030 S97020031 S97018567 S97020534 S97020412 S97020410 S97020411 SR99420635 S99010435-002 S97020414 S97020413 S97020797 S97020444 S97020445 S97020438 S97020796 * S97020360 * * * S97020466 S99527587 S97020470 INSTALLATION MANUAL SERVICE PARTS 1 22 PART NO. DESCRIPTION RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRC.
BCDJ SERIES C B O D E F G L H N M K H J I KEY NO. 9 10 11 12 13 14 * S97020029 S97020030 S97020031 S97018567 S97020534 S97020412 S97020410 S97020411 SR99420635 S99010435-003 S99010435-004 S97020414 S97020413 S97020797 S97020444 S97020445 S97020438 S97020796 * S97020360 RECIRCULATION COVER PLATE, BLACK (INCLUDING SCREWS) RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) RECIRC.
WARRANTY INSTALLATION MANUAL 24 Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC and Broan-NuTone Canada ULC (either being the“Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the“Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law).