ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS WITH
ROCKER SWITCH CONTROL
WARNING
!
For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service
disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards. Also, it is recommended to wear safety glasses and gloves.
ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS
Remove filters from the hood and set them aside.
NOTE: Some models have only one filter.
Remove the wiring cover (shaded part on illustration below)
retaining screw. Slide out the wiring cover from the hood and set
it aside with its screw.
Unplug the blower connector from the main harness.
NOTE: The illustrations in this procedure are generic; some hood details may slightly differ from the hood you have on hand but the
procedure itself applies to all single blower range hoods listed in this document (see page 3).
Wiring cover
screw
Using a 11/32'' socket, remove the 6 nuts retaining the blower
chamber to the hood assembly (2 nuts on inner back and 2 other
nuts per sides), then use a Phillips no. 2 screwdriver to remove
both front corner screws. See picture below for nuts and screws
locations. Pull out the blower chamber from the hood assembly
and set it aside with its retaining screws and nuts.
HE0253
HD0672
Nuts
Nuts
Screw
Remove and set aside the 4 front screws retaining the bent plate
to the hood.
HD0673
Screw locations
Fold back the bent plate to access to control panel connections.
HD0674
1
99045858A