WWW.BROAN-NUTONE.COM WWW.BROAN.
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cleaning and Maintenance . . . . . . . . . . . . . . . . . 6 Motors Grease Filters Non-Ducted Recirculation Filters Fan Wheels Stainless Steel Cleaning Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-21 INSTALLATION MANUAL TABLE OF CONTENTS Recommended Tools and Accessories for Installation . . . . . . . . . . . .
READ AND SAVE THESE INSTRUCTIONS ! Intended for domestic cooking only ! INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. For Broan products in U.S.A., register your range hood online at www.broan-nutone.com For Broan products in Canada, register your range hood online at www.broan.ca ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Use this unit only in the manner intended by the manufacturer.
! WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). c) Clean ventilating fan frequently. Grease should not be allowed to accumulate on fan, filters or in exhaust ducts. d) Use proper pan size.
BPDC1 SERIES BLOWER SWITCH I • II Turns blower on to LOW speed. Turns blower OFF. Turns blower on to HIGH speed. LIGHT SWITCH I • II Turns light on in LOW intensity. Turns light OFF. Turns light on to HIGH intensity. BPDP1 SERIES BLOWER SWITCH Turns blower OFF. I Turns blower on to LOW speed. II Turns blower on to HIGH speed. LIGHT SWITCH Turns light OFF.
Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTORS The motors are permanently lubricated and never need oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan wheel should also be replaced. GREASE FILTERS The grease filters should be cleaned frequently. Use a warm dishwashing detergent solution. Grease filters are dishwasher safe.
For ADA compliance installation guidelines, please type the model number into our website. Recommended Tools and Accessories for Installation • • • • • • • • • • • • • • • • • Measuring tape Phillips screwdriver no.
Contents Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: BPDC1 Series BPDP1 Series * FIND INSIDE ONE PACKAGING STYROFOAM OF HOOD (2) SHIELDED HALOGEN BULBS (50W, GU10) (2) GREASE FILTERS (1) 7” ROUND DUCT CONNECTOR (1) 3¼” X 10” DAMPER ASSEMBLY* (2) GREASE FILTERS EZ1 COMPONENTS Use this template for marking; do not attempt to cut out the ducting hole through it.
Prepare the Hood 1 ] If present, remove all protective polyfilm from the hood and/or parts. 2 ] Using the finger cup, remove the grease filters from the hood by pushing down and tilting filters out . B C 3 ] Remove both fillers by removing the 3 screws holding each one of them. Slide each one towards the center of the hood and tilt it up to remove it completely. Set the fillers and screws aside.
4 ] Remove both tape strips holding the 7” round adapter (not included with BPDC Series), and put the adapter aside. 5 ] Remove the screw holding the 3¼” x 10” adapter/damper and put the adapter/damper aside. Save this screw, it will be used later to hold the cover plate. 6 ] Remove the parts bag taped in the lower left corner of the hood.
8 ] Remove the EZ1 brackets from inside the hood by cutting off the tie wrap. Discard the tie wrap. EZ1 BRACKETS 9 ] Remove Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring) of hood. For knockout removed from back of hood, install an appropriate strain relief, 1/2” diameter (not included). For knockout removed from top of hood, the strain relief will be installed later.
DUCTED INSTALLATION ONLY 10 ] Remove 3¼” x 10” vertical, 3¼” x 10” horizontal (both are the rectangular central knockout plates, see hatched areas) or 7-inch round knockout plate as appropriate for your ducting method (see FIGURES 1 A and 1 B).
Prepare the Hood Location NOTE: Before starting installation, read all the steps of these instructions. Use the illustration below to identify your kitchen cabinet type. FRAMED CABINET FRAMELESS CABINET This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). For the standard installation, go to page 18.
4 ] Drill a 1/8” dia. pilot hole for house wiring, at B location on template. 5 ] Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the template. 6 ] Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall (horizontal exhaust).
FRAMELESS CABINET Refer to the marking on brackets to determine the correct installation side and orientation. X Y Z 3X [ \ 7/64” against the wall. Draw a line on the outer edge of the bracket (as shown). marked line, keeping the rear end edge leaning on the wall. Use a pencil to mark 3 holes. Remove the bracket. Using a 7/64” drill bit, drill 3 holes where marked. Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws.
Install the Hood (EZ1 Bracket) NOTE: The following procedure applies to both frame or frameless cabinet installations. 1 ] Run house power cable between service panel and hood location. 2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below); these holes allow the range hood to hang on the brackets (previously installed).
7 ] For framed cabinet, secure the hood to the EZ1 brackets using a 10” drill bit and 4 no. 8-18 x 1/2” metal screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in inset on illustration below). 8 ] For frameless cabinet, secure the hood to the cabinet using a 10” drill bit and 4 no. 8 x 5/8” round head wood screws (included in parts bag). Insert 2 screws per side, in the slots (as shown in inset on illustration below).
Standard Installation (without EZ1 brackets) 1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
Install the Hood (Standard Installation) NOTE: Two installers are recommended because of the weight of this hood. 1 ] Run house power cable between service panel and hood location. For hood with power cable access located on back of hood, run the house power cable into the hood through the strain relief previously installed in step 9 on page 11. For hood with power cable access located on top, tighten the strain relief to the power cable before inserting the strain relief in the knockout hole.
Connect the Wiring ! WARNING Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. MOTORS GROUND WIRE GROUND SCREW HOUSE POWER CABLE 1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Halogen Light Bulbs (BPDC1 Series only) The BPDC1 Series range hoods require two shielded Halogen Bulbs (120 V, 50 W max., MR16 or PAR16 with GU10 base), included. ! WARNING Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
Ground Line Neutral BK BK G/Y W Motor Lights BK (H) R (L) WIRING DIAGRAMS 120 V AC INSTALLATION MANUAL BL (H) Y (L) BK BL BN BN/W G/Y G/Y G/Y W BK (H) R (L) W BK (H) R (L) O R W Y COLOR CODE BLACK BLUE BROWN BROWN/WHITE GREEN/YELLOW W W 6 5 4 3 2 1 6 5 4 3 2 1 ORANGE RED WHITE YELLOW BK BK M W O BK G/Y R M FAN MOTOR W O BK G/Y R FAN MOTOR Ref: 990729459A Bulb Bulb BN/W BN BN/W BN BK BK BK BK C C BPDC1 SERIES (SECOND GENERATION)
W G/Y Ground Motor Line Neutral BK BK INSTALLATION MANUAL BK (H) R (L) WIRING DIAGRAMS 120 V AC Lights BL W BK BL BN BN/W 2 1 R BK G/Y G/Y W BK (H) R (L) W BK (H) R (L) 1 2 6 5 4 3 2 1 6 5 4 3 2 1 GREEN/YELLOW ORANGE RED WHITE Ref: 990729464A G/Y O R W COLOR CODE LED driver BLACK BLUE BROWN BROWN/WHITE BK W BK R 2 1 1 M W O BK G/Y R M FAN MOTOR W O BK G/Y R FAN MOTOR W 2 BN/W BN BN/W BN LED LED BK BK BK BK C C BPDP1 SERIES (SECOND GENERATION) 23
BPDC1 SERIES First Generation: Serial number 091810008492 and previous. B C D K L E F J G G H I KEY NO. PART NO.
BPDC1 SERIES Second Generation: Serial number 091810008493 and up.
BPDP1 SERIES C B First Generation: Serial number 091810008492 and previous. M D N E L K F G J G H I INSTALLATION MANUAL SERVICE PARTS KEY NO. 1 2 3 4 5 6 7 26 PART NO. S97020031 SR680508 S97020534 S97020412 S97020842 SR99420635 S97021337 S97020204-001 S97020204-002 8 S97020204-003 S97020204-004 9 S97020843 10 S97020797 11 S97020444 12 S97020425 13 S97020447 * S97020772 * S97020360 S97020465 S97020466 * S97020467 S97020468 * S99527587 * S97020470 * ITEM NOT SHOWN.
BPDP1 SERIES C B L D J G G H PART NO. S97020360 S97020465 S97020466 * S97020467 S97020468 * S99527587 * S97020470 * ITEM NOT SHOWN.
WARRANTY INSTALLATION MANUAL 28 Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC andVenmarVentilation ULC (either being the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law).