Specification Sheet

SPECIFICATION SHEET
Broan-NuTone LLC, 926 West State Street, Hartford, Wisconsin, USA 53027 Broan-NuTone.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
HK0268
TYPICAL SPECIFICATION
Range hood shall be Broan Model BUF4.
Unit shall be convertible between ducted using a washable
aluminum filter (included) and non-ducted (purchase non-
ducted filter separately).
Motor to be permanently lubricated. RPM not to exceed 2850.
Unit shall have a two-speed fan switch with separate light
switch.
Sides shall be mitered and bottom edge hemmed - with no
sharp edges.
Air delivery shall be no less than 160 CFM and sound levels
no greater than 7.5 Sones (3¼" x 10" vertical), 160 CFM at
7.0 Sones (horizontal discharge) or 190 CFM at 6.5 Sones
(7" round vertical). All air and sound ratings shall be certified
by HVI. Unit shall be U.L. listed.
Constructed with quality and good looks, the BUF4 is
superior to the competition whether ducted vertically,
horizontally, or non-ducted.
FEATURES
Max. Blower CFM: 230
120 V, 2850 RPM
Two speed fan control
Polymeric blade and light lens (accepts up to 75W bulb)
Washable aluminum filter
Converts to non-ducted by removing cover plate from front of
hood and installing the non-ducted filter (purchase separately)
Mitered sides and hemmed bottom for safety and good looks
3¼" x 10" damper/duct connector included
7" round damper must be purchased separately.
Available in 30" width
Contemporary styling in White, Black and Stainless Steel
12L 1106174B
BUF4 SERIES
TWO-SPEED
4-WAY CONVERTIBLE
RANGE HOOD
HVI-2100 CERTIFIED RATINGS comply with new
testing technologies and procedures prescribed by the
Home Ventilating Institute, for off-the-shelf products, as
they are available to consumers. Product performance
is rated at 0.1 in. static pressure, based on tests
conducted in a state-of-the-art test laboratory. Sones
are a measure of humanly-perceived loudness, based
on laboratory measurements.
Max. blower CFM indicates the performance of the hood blower in open air.
Can be used to comply
with LEED requirements.
* Center point for
7" round installation.
HVI PERFORMANCE
Duct Orientation Size Damper
Sones CFM
Normal High Normal
High
0.1 in. w.g.
Vertical - Rectangular 3¼ in. x 10 in. Included 4.0 7. 5 110 160
Horizontal - Rectangular 3¼ in. x 10 in. Included 4.5 7. 0 100 160
Vertical - Round 7 in. Sold separately 3.5 6.5 140 190

Summary of content (1 pages)