Installation Guide

MODELS BW5030SSL • BW5036SSL
Page 4
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This appliance
is equipped with a cord having a grounding wire with a
grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered
by the decorative flue and where it will not interfere
with the round duct. Make sure the outlet does not
interfere with the mounting bracket fastening area, ductwork,
or where the decorative flue touches the wall.
INSTALL THE WIRING
INSTALL THE HOOD MOUNTING
BRACKET
4”
22”
11
LOCATE
ELECTRICAL
OUTLET
WITHIN THESE
AREAS.
(Verify location
will not interfere
with duct,
mounting
brackets,
and flue.)
C
L
1. Construct wood wall framing that is flush with
interior surface of wall studs.
Make sure:
a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting bracket to be secured to the framing
within the dimensions shown.
2. After wall surface is finished, carefully center and
level the hood mounting bracket and secure it
to wall framing with (3) no. 8 x 1½” mounting
screws. Tighten the screws completely.
NOTE: Do not use drywall anchors.
7
7
8
40
5
8” = bottom of hood 30” above cooktop
3
15
16
FRAMING BEHIND
DRYWALL
1
9
16
WALL STUDS
NOTE:
Minimum hood distance above cooktop must not be less than 30”.
Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing
that ceiling height and flue length permit.
MOUNTING BRACKET LOCATION
(ABOVE 36” HIGH COOKTOP)
CEILING DUCT HOOD DISTANCE ABOVE 36” COOK TOP (SEE NOTE 1)
HEIGHT METHOD 30” 31” 32” 33” 34” 35” 36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET
DUCTED 40-5/8” 41-5/8” 42-5/8” 43-5/8” 44-5/8” --- ---
NON-DUCTED 40-5/8”
41-5/8” --- --- --- --- ---
9 FEET
DUCTED
---
---
42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
NON-DUCTED --- --- 42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
10 FEET
DUCTED
---
---
42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
NON-DUCTED --- --- 42-5/8” 43-5/8” 44-5/8” 45-5/8” 46-5/8”
NOTE:
On 8-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 34¾” (for ducted
discharge)
Minimum 30”, Maximum 31” (for non-ducted
discharge)
On 9-ft. ceilings
Hood distance above cooktop is:
Minimum 32”, Maximum 36” (for both ducted and
non-ducted discharge)
On 10-ft. ceilings
Hood distance above cooktop is:
Minimum 32”, Maximum 36” (for both ducted and
non-ducted discharge).
NOTE: 10-ft. ceilings require 10-ft. Flue
Extension, Model FXN58SS for ducted or
non-ducted installations
(purchase separately).