OPERATION
Fan Setting and Operation
Usethe“FAN”buttontochangethefanoperation.Thereare2choicesforfanoperation:“ON”or“AUTO”.
Thefactorypresetis“AUTO”.
“ON”–ThefanintheUltraAiredehumidierwillruncontinuously.Thisdoesnotaecteitherthe
dehumidicationorventilationfunctionsofthesystem.Thesystemmayormaynotbeventilatingor
dehumidifyingwhilethefanisrunning.Thissettingiscommonlyusedformaximumairltrationand/orair
recirculation.
“AUTO”–IndicatesthefanwillrunwhentheDEH3000/Rcallsfordehumidicationorventilation.
Ifthecontrolhasnotcalledfordehumidicationfor3hours,thecontrolwillautomaticallyrunthe
dehumidierfanfor10minutes.
Afteradehumidicationcycle,thefanautomaticallyshutsofor10minutes.Thispauseallowsthewaterto
drainfromthedehumidier.
Asolid“O”indicatesthefanisoperating.Aashing“O”indicatesthefanisinawaitmode.No“O”
indicates the fan is OFF.
To set the operation:
1. Pressandholdthe“FAN”button.Thecurrentfansettingwillbegin
toashonthedisplay.Releasethebutton.
2. Pressthe“FAN”buttontotogglebetweenthe“ON”and“AUTO”
modes.
Withthefaninthe“AUTO”mode,thefanwilloperateonlywhen
needed by other functions of the system. The fan will remain OFF
unless the system is dehumidifying or ventilating. The fan always
runsduringdehumidicationandventilationandthefan“O”icon
willbelit.TocompletelyturnthesystemOFF,usethe“ON/OFF”
button as described earlier.
Damper Operation and Ventilation, Manual (Hold) Mode
The“VENT”settingcontrolstheventilationfunctionofthesystem.Ithas
nocontroloverthedehumidicationfunction.Inordertoprovide
ventilation, the motorized damper must be open and the fan must be
running. The controller takes care of these two functions automatically
so that whenever the damper is open, the fan is running.
Theventilationindicator“O”willbedisplayedwhenevertheunitis
ventilating.Thefanoperationindicator“O”willalsobedisplayed.
There are three damper operation modes:
1. “OPEN”–holdmode:Thedamperwillbeopenandthedehumidier
fan will be continuously operating to introduce fresh air into the space.
Use this mode for continuous fresh air ventilation. The fan is always
on when the damper is open.
2. “CLOSED”–holdmode:Thedamperwillneveropen,andthe
dehumidierwillnotventilate.Thefanwillstilloperatenormallyfor
recirculationanddehumidication.
3. “PROGRAM”mode:TheDEH3000/Rwilloperatethemotorized
damperandthedehumidierfanaccordingtotheprogrammed
ventilationschedule(Page14).
Thefactorypresetforthe“VENT”settingis“CLOSED”.
To set “OPEN” – hold or “CLOSED” – hold ventilation operation:
1. Pressthe“VENT”button.Thecurrentsettingwillbegintoashonthedisplay.Releasethebutton.
2. Pressthe“VENT”buttonagaintoswitchbetween“OPEN”and“CLOSED”.
3. Leave the control alone for 10 seconds and your settings will be saved.