OPERATION
Fan Setting and Operation
Usethe“FAN”buttontochangethefanoperation.Thereare2choicesforfanoperation:“ON”or“AUTO”.
Thefactorypresetis“AUTO”.
“ON”–ThefanintheUltraAiredehumidierwillruncontinuously.Thisdoesnotaecteitherthe
dehumidicationorventilationfunctionsofthesystem.Thesystemmayormaynotbeventilatingor
dehumidifyingwhilethefanisrunning.Thissettingiscommonlyusedformaximumairltrationand/orair
recirculation.
“AUTO”–IndicatesthefanwillrunwhentheDEH3000/Rcallsfordehumidicationorventilation.
Ifthecontrolhasnotcalledfordehumidicationfor3hours,thecontrolwillautomaticallyrunthe
dehumidierfanfor10minutes.
Afteradehumidicationcycle,thefanautomaticallyshutsofor10minutes.Thispauseallowsthewaterto
drainfromthedehumidier.
Asolid“O”indicatesthefanisoperating.Aashing“O”indicatesthefanisinawaitmode.No“O”
indicates the fan is OFF.
To set the operation:
1. Pressandholdthe“FAN”button.Thecurrentfansettingwillbegin
toashonthedisplay.Releasethebutton.
2. Pressthe“FAN”buttontotogglebetweenthe“ON”and“AUTO”
modes.
Withthefaninthe“AUTO”mode,thefanwilloperateonlywhen
needed by other functions of the system. The fan will remain OFF
unless the system is dehumidifying or ventilating. The fan always
runsduringdehumidicationandventilationandthefan“O”icon
willbelit.TocompletelyturnthesystemOFF,usethe“ON/OFF”
button as described earlier.
Damper Operation and Ventilation, Manual (Hold) Mode
The“VENT”settingcontrolstheventilationfunctionofthesystem.Ithas
nocontroloverthedehumidicationfunction.Inordertoprovide
ventilation, the motorized damper must be open and the fan must be
running. The controller takes care of these two functions automatically
so that whenever the damper is open, the fan is running.
Theventilationindicator“O”willbedisplayedwhenevertheunitis
ventilating.Thefanoperationindicator“O”willalsobedisplayed.
There are three damper operation modes:
1. “OPEN”–holdmode:Thedamperwillbeopenandthedehumidier
fan will be continuously operating to introduce fresh air into the space.
Use this mode for continuous fresh air ventilation. The fan is always
on when the damper is open.
2. “CLOSED”–holdmode:Thedamperwillneveropen,andthe
dehumidierwillnotventilate.Thefanwillstilloperatenormallyfor
recirculationanddehumidication.
3. “PROGRAM”mode:TheDEH3000/Rwilloperatethemotorized
damperandthedehumidierfanaccordingtotheprogrammed
ventilationschedule(Page14).
Thefactorypresetforthe“VENT”settingis“CLOSED”.
To set “OPEN” – hold or “CLOSED” – hold ventilation operation:
1. Pressthe“VENT”button.Thecurrentsettingwillbegintoashonthedisplay.Releasethebutton.
2. Pressthe“VENT”buttonagaintoswitchbetween“OPEN”and“CLOSED”.
3. Leave the control alone for 10 seconds and your settings will be saved.