INSTALLATION INSTRUCTIONS HB0073 E60000 SERIES ! INTENDED FOR DOMESTIC COOKING ONLY ! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGE 13 AND 14. Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119 REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register SV08340 rev.
! WARNING ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 1. 2.
- E60000 SERIES RANGE HOOD SYSTEM INTERNAL BLOWERS MODEL 437 (HIGH MODEL 647 (7” ROUND WALL CAP) MODEL 441 CAPACITY ROOF CAP) (10’’ ROUND WALL CAP) MODEL 418 (10” ROUND MODEL 421 MODEL 643 (8” ROUND WALL CAP) 8” ROUND ADJUSTABLE ELBOW MODEL 415 7” ROUND ADJUSTABLE ELBOW) (10” ROUND VERTICAL IN-LINE DAMPER) MODEL 634 OR 644 (ROOF CAP) ADJUSTABLE ELBOW MODEL 407 (7” ROUND —2 FT. SECTIONS) MODEL 410 (10” ROUND DUCT —2 FT.
- E60000 SERIES RANGE HOOD SYSTEM IN-LINE AND EXTERIOR BLOWERS (HIGH MODEL 437 CAPACITY ROOF CAP) MODEL 441 MODEL HLB9 (800 CFM) (10” ROUND WALL CAP) OR HLB11 (1100 CFM) IN-LINE BLOWER MODEL 335 (1200 CFM) MODEL 331H (600 CFM) OR 336 (1500 CFM) (INCLUDES TWO 8” X 12” TO OR 332H (900 CFM) 10’’ ROUND TRANSITIONS) EXTERIOR BLOWER EXTERIOR BLOWER MODEL 643 (8” ROUND WALL CAP) MODEL 441 (10” ROUND WALL CAP) MODEL HLB6 (600 CFM) IN-LINE BLOWER (INCLUDES TWO 4½” X 18½” TO 10’’ ROUND TRANSITIONS) MODEL 421 (1
1. SELECT BLOWER OPTION AND INSTALLATION TYPE 1.1 NON-DUCTED INSTALLATION For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series. 1.
2. MEASURE INSTALLATION Dimensions for the most common installation are illustrated beside. Ceiling Cabinet, soffit, decorative flue or non-duct kit flue The minimum hood distance above cooktop must not be less than 24’’. A maximum of 30” above cooktop is highly recommended for best capture of cooking impurities. Distances over 30” are at the installer and users discretion.
3. PREPARE THE INSTALLATION (CONT’D) DUCTED INSTALLATIONS ONLY Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (vertical or horizontal).
5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY) Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below. VERTICAL DISCHARGE HORIZONTAL DISCHARGE 1 2 3 1 2 3 NOTE: For ducted installation only. HR0021 B A Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag).
8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY) All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel of the hood. The procedure below applies for one or two blowers. LEFT SIDE MOUNTING SCREW LOCATION Using a 5/16” socket, remove all blower mounting screws from the inner top of the hood.
9. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE) (INTERNAL BLOWER(S) HOOD ONLY) Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10” adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install an appropriate sized transition and seal the joints with duct tape. HJ0013 10.
13. INSTALL THE HOOD CAUTION Hold the hood until it is completely secured to the wood mounting strip. INTERNAL MOUNTING BLOWER(S) ONLY SCREWS LOCATION Run power cable to installation location. Remove the electrical compartment cover. Insert the cable in the hood and tighten the wire clamp to secure the cable. ALL INSTALLATIONS HD0264 Rest the back cavity of the hood on the wood mounting strip. WALL ANCHORS LOCATION Secure the hood to wood mounting strip with (4) screws no.
16. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER) Refer to instructions included with blower. Plug the 3-prong plug cord from rough-in plate to the 3-prong male connector inside the hood (A) and the 2-prong male connector cord from rough-in plate to the 2-prong plug inside the hood (B). B A ! WARNING Do not plug the 2 cords together. HE0078 17. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS Reinstall grease drip rail.
19. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood. Clean all-metal filters in the dishwasher using a non-phosphate detergent.
20. OPERATION (CONT’D) 3 4 2 1 A B HC0034 A) Halogen light knob B) Blower speed control knob HC0035 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blower switch 4) Blower speed control knob COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower.
22.
23. SERVICE PARTS Broan Elite E60000 Series Internal blower hoods Broan Elite E60000 Series Exterior or In-Line blower hoods 1 15 15 2 2 3 5 4 9 3 14 6 5 7 4 10 14 6 18 7 17 16 8 11 11 13 12 13 12 HL0105 HL0106 KEY NO. 1 2 3 4 5 6 7 8 9 PART NO. SV13296 SV17797 SV06750 SV16569 SV03435 SV08338 SV03501 SV08355 SV08343 SV08344 10 SV08097 11 12 13 14 15 * SV17640 SV17641 SV17642 SV17643 SV08337 SV17606 SV17609 SV08339 SV08093 SV08340 * SV08352 * NOT SHOWN.