INSTALLATION INSTRUCTIONS HB0072 E64000 SERIES ! INTENDED FOR DOMESTIC COOKING ONLY ! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14. Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119 REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register SV08341 rev.
! WARNING ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 1. 2.
- E64000 SERIES RANGE HOOD SYSTEM INTERNAL BLOWERS MODEL 441 (10” ROUND WALL CAP) MODEL 437 (HIGH CAPACITY ROOF CAP) MODEL 647 (7” ROUND WALL CAP) MODEL 634 OR 644 (ROOF CAP) MODEL 415 7” ROUND (10” ROUND MODEL 418 ADJUSTABLE ELBOW) MODEL 643 (8” ROUND WALL CAP) 8” ROUND ADJUSTABLE ELBOW ADJUSTABLE ELBOW MODEL 407 (7” ROUND 2 FT.
- E64000 SERIES RANGE HOOD SYSTEM IN-LINE AND EXTERIOR BLOWERS (HIGH MODEL 437 CAPACITY ROOF CAP) MODEL HLB9 (800 CFM) OR HLB11 (1100 CFM) IN-LINE BLOWER (INCLUDES TWO 8” X 12” TO 10’’ ROUND TRANSITIONS) MODEL 331H (600 CFM) OR 332H (900 CFM) MODEL 335 (1200 CFM) OR 336 (1500 CFM) EXTERIOR BLOWER EXTERIOR BLOWER MODEL 441 (10” ROUND WALL CAP) MODEL 643 (8” ROUND WALL CAP) MODEL HLB6 (600 CFM) IN-LINE BLOWER (INCLUDES TWO 4½” X 18½” TO 10’’ ROUND TRANSITIONS) MODEL 421 (10” RD. VERT.
1. SELECT BLOWER OPTION AND INSTALLATION TYPE 1.1 NON-DUCTED INSTALLATION For a non-ducted installation, a non-duct kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness, we recommend installing this kit with a single (internal) blower hood. The kit fits hoods from 30-inch width up to 48-inch width. See installation instructions included with the non-duct kit ANKE60 Series. 1.
2. PREPARE THE INSTALLATION CAUTION When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
2. PREPARE THE INSTALLATION (CONT’D) DUCTED INSTALLATIONS ONLY Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (vertical or horizontal).
4. REMOVE FILTERS AND GREASE DRIP RAIL A. Remove tape on filters. Remove filters from hood and set aside. NOTE: It is recommended to start with the center one(s). 1 B. Remove tape on grease drip rail (1). Lift out grease drip rail and set aside. HD0240 A B 5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY) SINGLE BLOWER HOOD Remove both screws retaining the adapter/damper (1) from inner top of the hood.
6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY) Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below. VERTICAL DISCHARGE HORIZONTAL NOTE: DISCHARGE 1 2 3 1 2 3 For ducted installation only. HR0021 A B Punch out the appropriate electrical knockout hole on top (A) or back (B) of the hood. Install the wire clamp (included in parts bag). NOTE: For a non-ducted installation, punch out the back electrical knock-out (B).
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY) Slide the blower to disengage its flange from the retaining bracket. HD0270 Flip the blower and engage its flange in the back wall retaining bracket. Using a 5/16” socket and the screws previously removed, secure the blower to the hood. RIGHT SIDE MOUNTING SCREW LOCATION LEFT SIDE MOUNTING SCREW LOCATION HD0271 HD0272 Plug the blower in. NOTE FOR DUAL BLOWER HOOD ONLY: Cut off the plastic tie wrap on left motor cable. HE0085 8.
10. INSTALL THE HOOD (ALL BLOWERS) INTERNAL BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the (4) 1/2” double thread screws at marked positions, leaving a 1/8” gap. Remove wiring cover. Insert the cable in the hood through the wire clamp and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it into position.
13. INSTALL LIGHT BULBS ! WARNING In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures. This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (not included). 1 2 1. Install lamps by placing the bulb leads into their grooves in the socket. 2. Gently push upwards and turn clockwise until secure.
15. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe. Allow filters to dry completely before reinstalling them in the hood. Clean all-metal filters in the dishwasher using a non-phosphate detergent.
16. OPERATION (CONT’D) 3 4 2 1 A B HC0034 A) Halogen light knob B) Blower speed control knob HC0035 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blower switch 4) Blower speed control knob COOKTOP LIGHTING (HALOGEN) A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity). BLOWER The blower is operated using two controls. Use the on/off rocker switch (3) to start and stop the blower.
18.
19. SERVICE PARTS Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods 1 15 2 14 3 5 4 3 5 6 4 7 9 15 14 2 6 18 7 17 10 8 16 11 11 12 12 13 13 HL0104 HL0103 KEY NO. 1 2 3 4 5 6 7 8 9 PART NO.