INSTALLATION INSTRUCTIONS HB0037 MODEL E662 ! INTENDED FOR DOMESTIC COOKING ONLY ! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626) REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register V06800 rev.
! WARNING ! WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. 1. 2. 3. 4. 5. 6. 7. 8. 9. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
TABLE OF CONTENTS BROAN ELITE E662 HOOD SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1. INSTALL DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2. PREPARE THE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3. CABINET PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BROAN ELITE E662 HOOD SYSTEM Model 634 or 644 (roof cap) Model 412 transition (3¼” x 10” to 7” round) 3¼” x 10” rectangular standard duct Model 647 (7” Rd wall cap) Model 634 or 644 (roof cap) Model 415 7” adjustable elbow (optional) 8” round adjustable elbow (optional) Model 407 7” Round standard duct 8” Round standard duct Model T460 transition (3¼” x 14” to 7” round) Model 643 (8” Rd wall cap) Model 459 transition (3¼” x 14” to 8” round) 3¼” x 14” rectangular standard duct Model 459 transiti
1. INSTALL DUCTWORK Plan where and how the ductwork will be installed. Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use 2” duct tape to seal duct joints. NOTE: When performing vertical exhaust ductwork, there must be at least 14” high free inside cabinet in order to allow cabinet blower installation. The minimum hood distance above cooktop must not be less than 24”.
3. CABINET PREPARATION ! WARNING The cabinet must be sized to support the total weight of the hood. For the E662 hood model, the total weight is 41 lb (19 kg). If the cabinet need to be reinforced, we suggest to add wood blocks the strengthen the connection between the bottom of the cabinet and its sides, as shown beside. ADD WOOD BLOCKS HD0139 4. CUTTING HOLES See figures below for cut-out dimensions in the bottom of the cabinet.
5. PREPARE THE HOOD S CREW L OCATION 5.1 Remove filters from the hood. Remove (3) screws holding both side panels to the hood and set aside. Remove both side panels. 3 2 1 HO0042 5.2 Punch out 2 knock-out holes for electrical connections (2 on top or one on top and one on back of the hood). 5.3 Attach one wire clamp on top of the hood for the provided electrical cable with 3-prong plug. Through the wire clamp, insert this electrical cable in the hood and tighten the wire clamp to secure the cable. 5.
6. INSTALL THE HOOD (CONT’D) 6.3 Attach the second wire clamp, insert the power cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Run power cable from hood up through slot cut in cabinet. Tighten the (4) screws completely, the add the last scerw (scerw no 5) in the center keyhole. 7. CABINET BLOWER PREPARATION 7.1 VERTICAL DISCHARGE ONLY 7.1.1 Seal the metal shutoff plate on the back of the cabinet blower using duct tape. 7.
8. INSTALL THE BLOWER IN THE CABINET 8.1 Install the cabinet in the cabinet and rest it on th e adapter plate. If a framed cabinet is used, insert the blower as show in pictures below. STEP 1 STEP 2 HH0052 HH0053 STEP 3 HH0054 8.2 VERTICAL DISCHARGE ONLY 8.2.1 Using four (4) no. 8 x 1/2” screws provided with hood, secure the adapter to the top of the cabinet below. Remove tape from damper flap. Seal the adapter to the cabinet below using tape. 8.3 HO0043 ALL DISCHARGE TYPES 2 1 8.3.
9. CONNECT WIRING ! WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Connect cable into wiring box using provided wire connectors. Connect wires as follow: WHITE to WHITE (A), BLACK TO BLACK (B), and GREEN or BARE wires under GREEN ground screws (C).
. LIGHT BULBS This hood must use 120V, 50W max., type MR16, GU10 shielded halogen lamps. (Purchase separately). ! WARNING In order to prevent the risk of personal injury, do not install a lamp identified for use only in enclosed fixtures. NOTE: The rings must be removed from bottom banel before installing halogen lamps. 11.1 Install the lamps by placing the bulb leads into their grooves in the socket and gently push upward and turn clockwise until secured. HE0047 11.
. OPERATION Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Allow the blower run for a few minutes to clear the air after you turn off the range. HC0017 A B A) Blower OFF Delay touch pad B) ON / Blower speed control touch pad C) OFF Blower touch pad / Filter maintenance touch pad C D E F D) OFF lighting touch pad E) Halogen light touch pad F) Nightlight / keyboard lock touch pad A.
. USE AND CARE Grease filters and side panels. The grease filters and the bottom panel should be cleaned frequently. Use a warm detergent solution. Remove grease filters by pushing them towards the back of hood and rotating downward. Clean all-metal filters in the diswasher using a non-phophate detergent. Discoloration of the filter may occur if using phosphate detergents, or as a result of local water conditions — but this will not affect filter performance.
. WIRING DIAGRAM ! WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. 120 V Supply Line BK Return W J5 BK 3 nc 2 W 1 BK W Light Socket W 50W max. BL Ground J6 Y 3 2 BK nc 1 Y W Y Light Socket 50W max.
. SERVICE PARTS E662 MODEL 1 2 3 4 5 6 9 8 7 9 12 13 10 HL0056 KEY no. 1 2 3 4 5 6 7 8 9 10 11 * * * * PART NUMBER V14971 V06242 V06243 V15931 V06263 V06262 V06750 V06741 V05917 V06268 V06265 V06266 V06733-2 V05921 V06734 V06745 V06746 V06776 V06784 V06800 * V06752 11 12 13 * 10 DESCRIPTION ADAPTER/DAMPER LEFT FLOW DEVIATOR RIGHT FLOW DEVIATOR CABINET BLOWER CONTROL PCB CONTROL FASCIA BROAN ELITE LOGO TRANSFORMER AND HARNESS KIT LAMP SOCKET TRIM RING FILTERS 9.922” X 17.981” FILTERS 12.
. WARRANTY WARRANTY BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.