BLOWER
A rotary 4-position knob (1) controls the blower (OFF - Low - Medium - High).
Turn the speed control knob clockwise to increase blower speed – counterclockwise to decrease
speed.
COOKTOP LIGHTING (HALOGEN)
Use the on/off rocker switch (2) to turn the halogen lights ON or OFF.
14. OPERATION
HC0059
1) B
LOWER SPEED CONTROL KNOB
2) H
ALOGEN LIGHT SWITCH
1
2
HEAT SENTRY™
This hood is equipped with a Heat Sentry™ thermostat. This thermostat is a device that will turn
on the blower if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to high speed.
2) If blower is already ON speed will remain the same.
When the temperature level drops to normal, the blower will return to its original setting.
The HEAT SENTRY can start the blower during a range top fire or other excessive
heat situations even if the hood is turned off. In this case, it is impossible to turn
the blower OFF using control panel switch. To stop the blower, set the main
power switch located behind the baffle filters in OFF position, if it is possible to
do so safely.
WARNING
!
HD0467
MAIN POWER
SWITCH