Spec Sheet

HRV150FL
Part HRV150FLS
66 to 150 CFM (0.4 in. w.g.)
THE ONE HRV YOU NEED FOR OPTIMAL
INDOOR AIR QUALITY
Homeowners who want the best in heat-recovery ventilation choose
the HRV150FL for its power, reliability and very quiet operation.
When used along with the VT8W IAQ wall control with SMART mode
(automated ventilation based on indoor relative humidity and outdoor
temperature), the HRV150FL allows you to optimize your ventilation
and your energy consumption. The HRV150FL represents over 15 years
of continuous improvement to deliver contractors the durability and
reliability they have come to expect from Broan.
Maintenance free, totally enclosed, sealed bearings motor; prevents
dust from entering
Pressure taps, balancing dampers and straps for insulated ducts for
quick, e ective installation
Integrated snap-in” drain system installs in seconds
with no additional parts
Reversible for greater installation  exibility
Recirculation mode, available with VT8W or VT7W main control, to
move air in homes without forced-air heating
Very quiet operation
REPAIRS AND MAINTENANCE
All parts of the HRV150FL can be removed in less than five minutes,
allowing direct access for easy repairs. The low power consumption
motor is permanently lubricated. Finally, the electronic circuit board
eliminates electromechanical parts, reducing repair time to a minimum.
WARRANTY
The HRV150FL is protected by a 5-year warranty on parts. The heat
recovery core is covered by a lifetime warranty, with the original proof
of purchase.
VB0298
Available at:
HEAT RECOVERY VENTILATOR
Controls
This unit is very simple to operate. Once it is installed, press on its
push button, located on the bottom of the unit, to activate it. Press
once for low speed, once again for high speed, and once more to
stop it.
For more convenience, this unit can also be controlled by an optional
main control. For a complete list of optional main and auxiliary
controls available, refer to the Wall Control Compatibility Chart
on last pages of wall controls speci cation sheet, available at
www.broan.com.
For more details about controls, refer to the Main and auxiliary wall
controls user guide, also available at www.broan.com.
Options
Complete line of registers and di users
Defrosting System
The HRV150FL uses an e cient defrosting method. No negative
pressure is created by air exhausted to the outdoors, as the air is
recirculated into the house, helping to prevent any backdraft.
Heat Recovery Core
Dimensions: 12” x 14” x 15.5”
Exchange surface: 102 ft
Weight: 6.2 lb
Material: Polypropylene
Type: Crossflow core
Warranty: Limited Lifetime
Requirements and Standards
Complies with the UL 1812 requirements regulating the installation
of Heat Recovery Ventilators
Complies with the CSA C22.2 no. 113 Standard applicable to ventilators
Complies with CSA F326 requirements regulating the installation of
Heat Recovery Ventilators
Technical data was obtained from published results of tests relating
to CSA C439 Standards
• HVI certi ed
VF0053
STALE AIR
FROM BUILDING
FILTRERED AIR
TO BUILDING
OUTDOOR TEMPERATURE DEFROST CYCLE (MINUTES)
°C °F DEFROSTING / OPERATING
WARMER THAN -5 WARMER THAN 23 NO DEFROST
-5 TO -15 23 TO 5 7 / 50
-15 TO -27 5 TO -17 7 / 25
-27 AND LESS -17 AND LESS 10 / 20