SPECIFICATIONS AND RATINGS
www.broan.com HRV150FLd20_04
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-877-862-7626)
Project: REMARKS
Location:
Part Number: HRV150FLS
Quantity:
Submitted by: Date:
DIMENSIONS: HRV150FL
Model: HRV150FL 6" Round Ports Speed Control on unit: Low and High speeds.
Part Number: HRV150FLS Housing: Pre-painted steel Other modes available with optional
Total Assembled Weight (including mainl wall controls.
polypropylene core): 65 lb. Insulation: Expanded polystyrene Heat Recovery Core:
Drains: 1/2"  ttings with - Heat Exchange Surface Area: 102 ft.
10 ft. PVC drain hose Mounting: Suspension by chains and springs - Type: Cross ow
Filters: 15 ppi washable reticulated foam - Material: Polypropylene
15.375" x 7.125" x 0.75" Supply & Exhaust Blower Motor: 1 PSC Motor
- Protection type: Thermally protected Unit Electrical Characteristics:
- Insulation class: B 120 volts, 60 Hz, 1.5 amps, 160 watts
VENTILATION PERFORMANCE
EXTERNAL STATIC
PRESSURE
NET SUPPLY
AIR FLOW
GROSS AIR FLOW
SUPPLY EXHAUST
PAIN. W.G. L/SCFMM/HL/SCFMM/HL/SCFMM/H
25 0.1 85 180 306 86 182 309 92 195 330
50 0.2 82 174 296 82 174 297 86 182 309
75 0.3 77 163 277 77 163 279 81 172 291
100 0.4 71 150 255 71 150 257 71 150 257
125 0.5 67 142 240 67 142 241 57 121 204
150 0.6 60 127 217 61 129 221 40 85 144
175 0.7 51 108 183 52 110 187 27 57 97
ENERGY PERFORMANCE
17
(432 mm)
17¼” (438 mm)
6”
(152 mm)
Power Cord
36” (914 mm)
Door
30¼” (768 mm)
35” (891 mm)
Terminal
Block
Location
Blower
Assembly
Motorized
Damper
Hooks Location
for Hanging Chains
Heat
Recovery
Core
VK0077A
SUPPLY
TEMPERATURE
NET AIR FLOW POWER
CONSUMED
WATT S
SENSIBLE
RECOVERY
EFFICIENCY
ADJUSTED
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS*
LATENT
RECOVERY
MOISTURE
TRANSFER
°C °F L/S CFM M3/H
HEATING
0 32 31 66 112 67 67 74 79 -0.01
0 32 40 85 146 74 65 71 75 -0.01
0 32 54 114 195 90 61 66 70 -0.01
-25 -13 38 81 138 87 60 64 76 0.02
0.8
0.6
0.4
0.2
0
5025 75 100 150 200
VG0089A
0
SUPPLY (L/S)
E
XHAUST (L/S)
125 175
EXTERNAL STATIC PRESSURE
IN
. W.G. (PA = N X 248.8)
CFM (L/S = CFM X 0.4719) (M/H = L/S X 3.6)
100
90
80
70
60
50
40
0 25 50 75 100
VG0090
APPARENT (%)
N
ET (%)
EFFICIENCY
AIR FLOW - L/S (0.47 L/S = 1 CFM
*Data not certi ed by HVI.
NOTE: All speci cations are subject to change without notice.