Installation Sheet
Line 120VAC, 60HZ
Green
Ground
Green
Ground
4B - INSTALLATION FOR TWO LOCATION CONTROL PREPARATION FOR UNIT SETTING SETTING FOR DIFFERENT MODES
QUICK TEST
Hot (Black)
Neutral (White)
Black Red
Black
White
Load
Black
Red
Floor
Side View Top View
4.0’
(1.2m)
35’
(10.7m)
15’ 
35’
(10.7m)
TIME
SENSOR
LIGHT
Fresnel Lens
0
COVERAGE PATTERNS
The sensor detects motion in areas up to 900 sq. ft. and up to 35 
feet from the sensor. Ideally, the sensor is designed for small 
amounts of motion in space up to 300 sq. ft. The fresnel lens on 
the sensor is a multiple segment viewing lens with a field of view 
of 180°. The sensor must have a clear view of the people in the 
space in order to detect occupancy. Obstructions, such as 
furniture blocking the sensor’s lens, may prevent occupancy 
detection.
Connect wires per wiring diagram as follows:
1. Connect green ground or bare copper wire in the wall box to the 
Green wire of the device.
2. Connect Hot wire in the wall box to the Black wire of the device.
3. Connect Load wire(s) and Traveler wire in the wall box wire to 
the Red wire of the device.
4. Screw wire connectors on clockwise making sure no bare 
conductors show below the wire connectors. Secure each 
connector with electrical tape.
5. Mount device in the wall box with screws and mount wall plate.
6. Repeat step 1-6 for installing another sensor switch to the wires 
in the wall box. (the load wire may only exists in one wall box)
7. Restore power at circuit breaker or fuse. Installation is complete.
8. Turn on the power, manually press the switch button to check 
whether the product is installed correctly, and at the same time 
ensure that the LED light in the fresnel lens flashes. Wait about 
40s for product booting, the product will work properly.
1. Pry off the top cover with a slotted screwdriver.
2. Set 3 controls of TIME, SENSOR and LIGHT after cover is off.
Set delay TIME to "0" to automatically turn off the light after 30 
seconds and set LIGHT to “ • ” to disable light sensitivity, this 
allows you to quickly check the sensor coverage area. 
NOTE: 
1. Either sensor can turn the lights ON. 
2. Either sensor must time-out to OFF, or both manual buttons 
must be pressed for the lights to turn OFF.
3. A ground connection is required to operate. Use the ground 
wire in the wall box for ground connection. If no ground is 
available, consult an electrician. Device will not function if it is 
not grounded.
4. The hot (black wire) and load (red wire) must be correctly 
connected as stated above, otherwise the device will not 
function. If the light never turns on, then try to reverse the hot 
and load wiring of either or both sensors.
Disable Automatic OFF function
Automatically turn off the light after 30 seconds
Automatically turn off the light after 5 minutes
Automatically turn off the light after 15 minutes
Automatically turn off the light after 30 minutes
0
1
2
3
TIME NOTE
Disable Automatic ON function
Automatically turn on the light in dark environment
Automatically turn on the light in brighter environment than LIGHT 1
Automatically turn on the light in any light environment, including 
the bright day
1
2
3
NOTE
LIGHT
Top Cover 
(Manual Switch)
Delay Time Sensor Sensitivity Light Sensitivity
Manual Switch
A. Automatic ON & Automatic OFF Mode:
1. Set human body SENSOR sensitivity as desired.
2. Set delay TIME to "0" (30 seconds), “1” (5 minutes), “2” (15 
minutes) or "3" (30 minutes) as desired.
3. Set LIGHT sensitivity to “1”, “2” or "3" as desired.
For LIGHT "1", it will automatically turn on the light only in dark 
environment, like during the night. 
For LIGHT “2”, it will automatically turn on the light in brighter 
environment than LIGHT “1”. 
For LIGHT "3", it will automatically turn on the light in any light 
environment, including the bright day. (Default Setting: 30 
seconds delay TIME, maximum SENSOR sensitivity, maximum 
LIGHT sensitivity)
B. Manual ON & Automatic OFF Mode:
1. Set human body SENSOR sensitivity as desired.
2. Set delay TIME to "0" (30 seconds), “1” (5 minutes), “2” (15 
minutes) or "3" (30 minutes) as desired.
3. Set LIGHT sensitivity fully counterclockwise to “ • ” to disable 
automatic ON function.
C. Manual ON & Manual OFF Mode:
1. Set delay TIME fully counterclockwise to “ • ” to disable 
automatic OFF function.
2. Set LIGHT sensitivity fully clockwise to “3”.
Human body SENSOR function will be disabled automatically.
(4.6m)
Broan
Hartford, WI 53027
www.broan.com www.nutone.com
800-558-1711 888-336-3948         1101846A
TIME SENSOR LIGHT
Green
Black
Red
Ground
Neutral
Traveler 
Hot
Load
Green
Black
Red
Ground
Neutral
Traveler 
Hot
Wall Box 1 Wall Box 2
Wall Box 1 Wall Box 2
For Warranty Statement, Service Parts, Technical 
Support, or to Register your product, please visit our 
website or call:
In the United States - Broan.com 800-637-1453 or 
NuTone.com 888-336-6151. In Canada - Broan.ca or 
NuTone.ca 877-896-1119