Installation guide

BROAN
ALLUREĀ®
QSE1
SERIES
RANGE
HOOD
CONNECT
WIRING
WARNING:
To
reduce
the
risk
of
electric
shock,
make
sure
power
is
switched
off
at
the
service
panel.
Lock
or
tag
service
panel
to
prevent
power
from
being
switched
on
accidentally.
GREEN
SCREW
Connect
House
Wiring
(120
VAC)
to
hood.
Connect
house
black
to
hood
black
wire,
house
white
to
hood
white
wire,
and
house
ground
under
Green
Ground
Screw.
Securely
tighten
cable
clamp
onto
house
wiring.
Replace
wiring
cover.
Page
4
INSTALL
HOOD
(4)
\
MOUNTING
SCREW
(4)
Hang
hood
from
(4)
Mounting
Screws
(from
parts
bag).
Slide
hood
towards
wall
until
mounting
screws
are
engaged
in
narrow
end
of
(4)
Keyholes.
Tighten
mounting
screws
securely.
CAUTION
||
DO
NOT
PUSH
ON
FAN
BLADE.
Pushing
on
the
blade
may
cause
it
to
interfere
with
other
hood
parts.
TAPE
Connect
ductwork
to
hood.
Use
Duct
Tape
to
make
joints
secure
and
air
tight.
KEYHOLE
DUCT