Install Instructions

MODEL RD4
RADIATION DAMPER
INSTALLATION INSTRUCTIONS
For Use In 1, 2 or 3 Hour Rated Floor-Ceiling and Roof-Ceil-
ing Designs
Horizontal Mount Only
For Use With The Following Fan Models:
Fan Models
Broan HD50, HD80, 676, 684
NuTone HD50NT, HD80NT, 676NT, 684NT
1. Position radiation damper on the inlet side of the fan so that the
arrow in the damper will point UP in the nished installation.
Attach the damper to the fan using #8 (M4) sheet metal screws
(provided). There must be a minimum of two connections on each
of two opposite sides. Care must be taken to ensure that the
fasteners do not interfere with the closing of the damper curtain.
For best results, use mounting holes provided.
2. Position fan/damper assembly so that the inlet face of the radia-
tion damper is ush with the nished surface of the ceiling. Fasten
fan/damper assembly to the building structure by driving #10 (M5)
minimum sheet metal screws or #8d minimum nails through the
fan mounting brackets and into the ceiling joists. There must
be a minimum of two fasteners on each of two opposite sides.
Ceiling opening must be no larger than the inlet opening of
the damper.
3. New Construction
A housing mask has been provided to keep construction dust,
drywall spray, paint, etc. from damaging the radiation damper
of blower assembly.
a) Bend up the small tab of the mask.
b) Tuck the opposite side of the mask under one of the damper’s
grille mounting ears and push mask up into damper housing.
Note: Mask can be put in place before or after the blowers as-
sembly is installed.
Remove mask before installing grille or operating fan.
4. Attach the metal grille, supplied, over the inlet face of the radia-
tion damper using #8 (M4) sheet metal screws (provided). There
must be a minimum of one screw on each of two opposite sides.
For best results, use mounting holes provided.
English
English
1
2
3
4
ITEM PART NO. DESCRIPTION
1 99523579 Fusible Link
2 99260485 Sheet Metal Nut
3 99170245 Damper Screw
4 99150573 Grille Screw
5 99523357 Radiation Damper
-- 98009908 Metal Grille
-- 97015727 Metal Duct Connector
For replacement
parts telephone
1-800-558-1711
99043769A
5
WARNOCK HERSEY LISTING
INCLUDES DAMPER ONLY. IT
DOES NOT INCLUDE EXHAUST
FAN. DAMPERS MAY BE USED
WITH UL LISTED FAN MODELS
NOTED.
16” OR 24” ON CENTER
FASTENER
FAN
MOUNTING
BRACKET
GRILLE
GRILLE SCREW
CEILING
DAMPER
WOOD
FRAMING
MEMBER
OR JOIST
WARNOCK HERSEY LISTED