Installation guide

®
MODELS RM325H & RM326H
l
(for use with RM60000 Series Range Hoods)
WARNING
NOTE: These b_owers are compatibme with o_der
"60000 Series" Rangemaster ® Hoods. Refer to the
installation instructions incmudedwith the hood,
visit www.breanocom, or contact Technicam
Support.
TO REDUCE THE R_SK OF F_RE, ELECTRIC SHOCK, OR iN-
JURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power
from being switched on accidentalIy. When the service dis-
connecting means cannot be Iocked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by quali-
fied personnel in accordance with alI applicabIe codes and
standards, including fire-rated construction codes and stan-
dards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting.FolIow the heating equipment
manufacturer's guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or driIIing into wall or ceiIing, do not damage
electrical wiring and other hidden utilities.
6. Dacted fans must always be vented to the outdoors.
7. Do not use this range hood with any additionaI solid-state speed
control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RiSK OF A RANGE TOP GREASE RRE:
a) Never leave surface units unattended at high settings. Believers
cause smoking and greasy spiIIovers that may ignite. Heat
oils siowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when cook-
ing flaming foods.
c) CIean ventilating fans frequently. Grease should not be aI-
lowed to accumuIate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
TO REDUCE THE R_SK OF _NJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE RRE,OBSERVE THE FOL-
LOWING*:
1_ SMOTHER FLAMES with a close-fitting Iid, cookie sheet, or
metaI tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDI-
ATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN -You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels -
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a CIass ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For general ventiIating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This biower has a thermal overload which will automatically
shut off the motor if it becomes overheated.The motor will re-
start when it cools down.If the motor continues to shut off and
restart, have the hood serviced.
4. For best capture of cooking impurities, the bottom of the hood
should be a minimum of 24" and a maximum of 30" above the
cooking surface.
5. Please read specification label on product for further informa-
tion and requirements.
6. To reduce the risk of fire and to properly exhaust air on a ducted
installation, be sure to duct air outside - Do not exhaust air
into spaces within walls or ceiling or into attics, crawl spaces,
or garage.
7. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to pre-
vent power from being switched on accidentally, switch power
off at service panel and Iock or tag service panel.
8. The RM325H & RM326H Blowers must be installed with
RM60000 Series Range Hoods only. Other Range Hoods can-
not be substituted. (Range Hood sold separately.)
Save this manual for Electrical
Inspector and Homeowner to use.

Summary of content (20 pages)