Product Overview

SPECIFICATIONS
Project: REMARKS
Location:
Part no.:
Qty.:
Submitted by: Date:
D
IMENSIONS: BROAN™ ERV70S
(Side Ports)
16
5
/16
15
1
/16
15
5
/8
VK0074A
2
3
/8
18
5
/8
Ø 4” TYP .
3 FT .
P
OWER C ORD
15
7
/16
1
2
3 4
VENTILATION PERFORMANCE
ENERGY PERFORMANCE
SUPPLY
T
EMPERATURE
NET AIR FLOW
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
LATENT RECOVERY/
MOISTURE
TRANSFER
°C °F L/S CFM M
3
/H
HEATING
0 32 17 35 60 34 66 77 0.59
0 32 30 64 109 50 60 69 0.54
-25 -13 17 36 61 43 56 75 0.55
C
OOLING TOTAL RECOVERY EFFICIENCY
35 95 17 36 61 34 50
15
16
15
5
/8
16
5
/
16
2 ³/8
15
7
/16
19
13
/16
Ø 4” TYP .
3
FT
.
P
OWER
C
ORD
1
2
3 4
EXTERNAL
STATIC PRESSURE
NET SUPPLY
AIR FLOW
GROSS AIR FLOW
SUPPLY EXHAUST
PA IN. W.G. L/S CFM M
3
/H L/S CFM M
3
/H L/S CFM M
3
/H
25 0.1 39 82 139 39 85 143 39 83 141
50 0.2 37 78 133 38 81 136 37 79 134
75 0.3 35 75 127 36 78 131 35 75 127
100 0.4 33 70 119 34 73 122 34 71 121
125 0.5 32 67 114 33 71 117 32 67 114
150 0.6 29 62 105 30 66 109 29 61 104
175 0.7 28 59 100 28 61 102 27 57 97
200 0.8 26 55 93 26 57 95 24 52 88
:tinU no lortnoC deepS leets detniap-erP :gnisuoH
Part Number Top Ports: Insulation: Expanded polystyrene - Low speed and high speed
elbaliava sedom rehtO - :stroP ediS rebmuN traP
Total Assembled Weight (including Mounting: Suspension by chains and with auxiliary wall controls
polymerized paper core): 34 lb. (15.2 kg) spring or optional Energy Recovery Core:
tekcarb llaw strop 4 dnuoR - Heat Exchange Surface Area: 42.3 ft.
2
(3.9 m
2
)
ow
Core Filters: 2 washables, MERV 6 Supply and Exhaust Blower Motor: 1 motor - Material: Polymerized paper
9.2” x 5.75” x 0.38” - Protection type: Thermally protected Unit Electrical Characteristics:
sttaW erepmA ycneuqerF stloV B :ssalc noitalusnI - )mc 1 x mc 6.61 x mc 4.32(
120 60 Hz 0.5 60
1: FRESH AIR TO BUILDING PORT
2: EXHAUST AIR FROM BUILDING PORT
3: FRESH AIR FROM OUTSIDE PORT
4: EXHAUST AIR TO OUTSIDE PORT
NOTE: ALL UNITS PORTS WERE CREATED TO BE CONNECTED TO DUCTS HAVING A MINIMUM OF 4” DIAMETER, BUT IF NEED BE, THEY CAN BE CONNECTED TO
BIGGER SIZED DUCTS BY USING AN APPROPRIATE TRANSITION (E.G.: 4” DIAMETER TO 5” DIAMETER TRANSITION).
BROAN™ ERV70T
(Top Ports)
1: FRESH AIR TO BUILDING PORT
2: EXHAUST AIR FROM BUILDING PORT
3: FRESH AIR FROM OUTSIDE PORT
4: EXHAUST AIR TO OUTSIDE PORT
NOTE: ALL UNITS PORTS WERE CREATED
TO BE CONNECTED TO DUCTS HAVING A
MINIMUM OF 4” DIAMETER, BUT IF NEED
BE, THEY CAN BE CONNECTED TO BIGGER
SIZED DUCTS BY USING AN APPROPRIATE
TRANSITION (E.G.: 4” DIAMETER TO 5”
DIAMETER TRANSITION).
www.broan.com
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
99528488A