installation guide

Cut out this 4½” diameter circle
all the way through the wall.
Cut out this 6¾” diameter square
only through the siding.
Cut out on dotted lines.
wall cap for 4-inch round duct
installation instructions
1. Cut out template below and trace
outline on wall. Avoid placement
where house wiring or plumbing is
located.
3. Connect METAL DUCT CONNECTOR to-
gether. Snap SLOTS in DUCT into TABS on
VENT COVER.
99044140A
2. Cut 4½” DIAMETER HOLE all the
way through the wall. If wall is not
flat: Remove any siding or other
outer wall covering from inside 6¾”
SQUARE - to create a at surface.
SLOTS
TABS
VENT COVER
METAL
DUCT CONNECTOR
4½” DIAMETER HOLE
6¾” SQUARE
5. Insert duct through hole in wall and fasten duct to
metal duct connector. Use duct tape on all connec-
tions to make them secure and air-tight.
DUCT
4. Attach DUCT to fan’s DUCT CON-
NECTOR.
6. Secure vent cover to wall with 4 SCREWS
(included). Caulk around vent cover with
a quality caulking compound.
DUCT
CONNECTOR
CAUTION
For dryer
installations:
Use rigid metal
duct only.