Product Overview

Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
SPECIFICATION SHEET
41F 99044914D
MODEL XB110H
VENTILATION FAN
FEATURES
ULTRASMART™ DC Motor and Control Technology
DC motor for efficiency well beyond ENERGY STAR
®
requirements.
Can be used to comply with ASHRAE 62.2, LEED, ENERGY
STA R
®
for Homes and CA Title 24.
Powerful operation maintained over a wide range of real-world
installations (CFM ratings maintained through at least 0.25”
static pressure).
Rated for Continuous Operation.
ULTRASILENTSound Technology
HVI certified, best-achievable <0.3 Sone level provides nearly
silent operation for a relaxing environment.
State-of-the-art blower and duct outlet design smooths airflow.
High tech DC motor designed for nearly silent operation.
ULTRAQUICKInstallation Technology
Unique telescoping mounting frame fits through retrofit drywall
opening to allow easy installation from the room side. No attic
access needed!
Captive screws allow for easy new construction installation.
Mounting frame positioning tabs provide easy vertical
positioning for new construction.
Easy to insert and remove snap-in housing. No screws
required!
Easy to insert and remove snap-in blower.
Inside or outside duct connector and knockout plate mounting
provides flexibility for new construction or retrofit.
ULTRASENSE™ Humidity Sensing Technology
Detects humidity at the ceiling where it is greatest, which
minimizes reaction time.
Automatically turns fan on when either of these conditions is
detected:
- Rapid to moderate humidity increase;
- Humidity above set-point (50%-80% RH).
Humidity level is set with easily accessible user adjustment.
DIMENSIONS (Inches)
SPANS 14 TO
24 ON-CENTER
FRAMING
Can be used to comply with CALGreen standards.
Two wire manual operation for odor control - Turns fan ON
when power line through wall switch is cycled ON, OFF and
back ON.
After humidity has stabilized and is below set-point or after
manually initiated through power line cycling, fan remains on
until user adjustable (5 to 60 minutes) time delay set point is
reached.
U.L. Listed for use over bathtubs and showers when connected
to a GFCI protected branch circuit (ceiling mount only).
Use only ON/OFF switch, mechanical timer or relay-switched
control.
3-year warranty.