Technical data
Brocade SilkWorm 4100 Hardware Reference Manual A-5
Publication Number: 53-0000563-02
General Specifications
A
General Specifications
Table A-4 lists the general specifications for the SilkWorm 4100.
Table A-4 General Specifications
Specification Description
Configurable port types F_Port, FL_Port, and E_Port
EMC (electromagnetic
compatibility)
Emissions
An operating SilkWorm 4100 conforms to the emissions
requirements specified by the following regulations:
• FCC Rules & Regulations, Part 15 subpart B, Class A
• CSA C108.8 Class A
• VCCI Class A ITE
• CISPR 22 Class A
• EN55022 Class A
• AS/NZF 3548: 1995 Class A
• Korean EMC Requirements
• BSMI Standard CNS 13438
• EMC Directive 89/336/EEC
• EN5022 Level A
• EN50082-2/EN55024: 1998
• CNS13438 Class A
• ICES-003 Class A
Immunity
• IEC 61000-4-2 Severity Level 3 for Electrostatic
Discharge
• IEC 61000-4-3 Severity Level 3 for Radiated Fields
• IEC 61000-4-4 Severity Level 3 for Fast Transients
• IEC 61000-4-5 Severity Level 3 for Surge Voltage
• IEC 61000-4-6 Conducted Emissions
• IEC 61000-4-11 Voltage Variations
• EN 61000-4-12 Oscillatory Waves Immunity
• EN 61000-3-2 Limits for Harmonic Current Emissions
• EN 61000-3-3 JEIDA
System architecture Nonblocking shared-memory switch
System processor PowerPC 440GP, 400 MHz CPU
ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface
standard)
Modes of operation Fibre Channel Class 2 and Class 3
Fabric initialization Complies with FC-SW-3 Rev. 6.6
FC-IP (IP over Fibre Channel) Complies with FC-IP 2.3 of FCA profile
Aggregate switch I/O bandwidth 256 Gbit/sec if all 32 ports are running at 4 Gbit/sec, full duplex
Port-to-port latency Less than 2 microseconds with no contention (destination port
is free)