Technical data
Fabric OS Administrator’s Guide 5-7
Publication Number: 53-0000518-09
Setting Chassis Configurations
5
Table 5-3 lists the supported configurations options for Fabric OS v5.0.1.
The following sections contain procedures for obtaining chassis information and for configuring
director domains using the chassisConfig command.
Table 5-3 Supported Configuration Options
Option Number
of
Domains
Maximum
Number of Ports
Per Switch
Supported Port
Blades
Supported
CP Blades
Notes
1 1 128 FC2-16, FC4-16 CP2 or CP4 CP4 fits all
chassis
except the D2
chassis.
Option 1 is
the default
configuration
for SilkWorm
24000.
22 64/64 FC2-16 CP2
3 2 64/64 Left side: FC2-16
Right side: FC-16
CP2
4 2 64/64 Left side: FC-16
Right side: FC2-16
CP2
5 1 256 FC4-16, FC4-32 CP4 CP4 fits all
chassis
except the D2
chassis.
Option 5 is
the default
configuration
option for
SilkWorm
48000.
Option Result
1 One 128-port switch (Blade IDs 4, 17 on slots 1-4, 7-10. Blade ID 5 and 16 on slots 5, 6)
2 Two 64-port switches (Blade ID 4 on slots 1-4, 7-10. Blade ID 5 on slots 5, 6)
3 Two 64-port switches (Blade ID 4 on slots 1-4; ID 2 on slots 7-10. Blade ID 5 on slots 5, 6)
4 Two 64-port switches (Blade ID 2 on slots 1-4; ID 4 on slots 7-10. Blade ID 5 on slots 5, 6)
5 One 256-port switch (Blade IDs 4, 17, and 18 on slots 1-4, 7-10. Blade ID 16 on slots 5, 6)