Technical data
6-6 Fabric OS Administrator’s Guide
Publication Number: 53-0000518-09
Viewing Routing Path Information
6
Example
3. Use the uRouteShow command to display unicast routing information.
SilkWorm 200E, 3016, 3250, 3850, 3900, 4012, and 4100: Use the following syntax:
urouteshow [portnumber][, domainnumber]
SilkWorm 12000, 24000, and 48000: Use the following syntax:
urouteshow [slot/][portnumber][, domainnumber]
The following entries appear:
Local Domain Domain number of the local switch.
In Ports Port from which a frame is received.
Domain Destination domain of the incoming frame.
Out Port The port to which the incoming frame will be forwarded in order to reach the
destination domain.
Metric Cost of reaching the destination domain.
Hops The maximum number of hops to reach the destination domain.
Flags Indicates if the route is dynamic (D) or static (S). A static route is assigned using
the command uRouteConfig.
Next (Dom, Port) Domain number and port number of the next hop.
switch:admin> topologyshow
2 domains in the fabric; Local Domain ID: 1
Domain: 6
Metric: 500
Name: switch
Path Count: 4
Hops: 1
Out Port: 60
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 61
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 62
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D
Hops: 1
Out Port: 58
In Ports: None
Total Bandwidth: 2 Gbps
Bandwidth Demand: 0%
Flags: D