Technical data

Fabric OS Administrator’s Guide 9-9
Publication Number: 53-0000518-09
Viewing Equipment Status
9
To display the status of a power supply
1. Connect to the switch and log in as admin.
2. Enter the psShow command:
The possible status values are:
OK Power supply functioning correctly.
Absent Power supply not present.
Unknown Unknown power supply unit installed.
Predicting failure Power supply is present but predicting failure.
FAULTY Power supply is present but faulty (no power cable, power switch turned off, fuse
blown, or other internal error).
To display temperature status
1. Connect to the switch and log in as admin.
2. At the command line, enter the tempShow command:
Information displays for each temperature sensor in the switch.
The possible temperature status values are:
OK Temperature is within acceptable range.
FAIL Temperature is outside of acceptable range. Damage might occur.
switch:admin> psshow
Power Supply #1 is OK
0335,FF2Z0007161,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007161
Power Supply #2 is faulty
0335,FF2Z0007176,60-0000739-02, B,,DCJ3002-01P, B,FF2Z0007176
switch:admin>
switch:admin> tempshow
Index Status Centigrade Fahrenheit
----------------------------------------------------
1 OK 21 70
2 OK 22 72
3 OK 29 84
4 OK 24 75
5 OK 25 77
switch:admin>