Technical data

Fabric OS Administrator’s Guide 11-5
Publication Number: 53-0000518-09
Choosing an Extended ISL Mode
11
If you set one external port to L2 (60 km) and the other external port is an E_Port, then one internal
port is disabled.
Setting both external ports to L1 (50 km) disables two internal ports.
Setting one external port to L1 (50 km) and the other external port to L0.5 (25 km) disables one
internal port.
If you set one external port to L1 (50 km) and the other external port is an E_Port, then one internal
port is disabled.
Setting both external ports to L0.5 (25 km) disables one internal port.
SilkWorm 3250, 3850, 3900, 12000, 24000, and 48000 (FC2-16 port blades)
The number of ports that can be configured per port group at various distances is summarized
in Table 11-4.
SilkWorm 4100
The number of ports that can be configured at various distances is summarized in Table 11-5.
Table 11-4 SilkWorm 3250, 3850, 3900, 12000, 24000, and 48000
(FC2-16 port blades)
Speed
(Gbit/sec)
Number of Ports Allowed at Distance (km)
10 km 25 km 50 km 100 km 250 km 500 km
1 4 ports 4 ports L1 mode: 4
ports
LD mode: 3
ports
up to 2
ports
n/a n/a
2 4 ports 3 ports up to 2
ports
1port n/a n/a
4 n/a n/a n/a n/a n/a n/a
Table 11-5 SilkWorm 4100
Speed
(Gbit/sec)
Number of Ports Allowed at Distance (km)
10 km 25 km 50 km 100 km 250 km 500 km
1 32 ports 32 ports 32 ports up to 15
ports
up to 6
ports
up to 3
ports
2 32 ports 32 ports up to 15
ports
up to 7
ports
up to 3
ports
n/a
4 32 ports up to 15
ports
up to 7
ports
up to 3
ports
n/a n/a