Technical data

A-12 Fabric OS Administrator’s Guide
Publication Number: 53-0000518-09
Converting Port Number to Area ID
A
Example: Configure Command on a Switch Running Fabric OS 5.0.1
Converting Port Number to Area ID
Except for the following cases, the area ID is equal to the port number:
when you perform a port swap operation
when you enable Extended Edge (also known as “displaced PID”) PID on the director
If you are using Extended Edge PID format (for example, the SilkWorm 48000 with configuration
option 5) and would like to map the output of the port number to the area ID, use the following formula
(for ports 0-127):
where:
a area
p port number
% modulus (or remainder)
configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [11]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
WAN_TOV: (0..30000) [0]
MAX_HOPS: (7..19) [7]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
Switch PID Format: (1..2) [1] 2
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
BB credit: (1..27) [16]
Insistent Domain ID Mode (yes, y, no, n): [no]
Virtual Channel parameters (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
RSCN Transmission Mode (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
ssl attributes (yes, y, no, n): [no]
http attributes (yes, y, no, n): [no]
snmp attributes (yes, y, no, n): [no]
rpcd attributes (yes, y, no, n): [no]
cfgload attributes (yes, y, no, n): [no]
webtools attributes (yes, y, no, n): [no]
Switch PID format has changed to PID Format 2 ('Extended Edge PID')
a = (p + 16) % 128