Brocade Switch Requirements
B
Brocade Switch Requirements
Following are the SilkWorm software requirements:
• 2000-series models must be running Fabric OS v2.6.0 or later.
• 3000-series models must be running Fabric OS v3.1.0 or later.
• 3016, 3250, 3850, 3900, 12000, and 24000 models must be running 4.2.0 or later.
• 4100 model must be running Fabric OS v4.4.0 or later.
• 4012 model must be running Fabric OS v5.0.0 or later.
• 200E model running Fabric OS v5.0.1 or later.
• 48000 model must be running Fabric OS v5.0.1 or later.
• A zoning license and a fabric license must be installed on each Brocade switch.
Supported Brocade Features
The following features are supported on Brocade switches in interoperability mode:
• Brocade Fabric Watch
• Brocade Fabric Access API functions
Accessible from Brocade switches only, but switch information for non-Brocade switches is
reported. The object information and zoning actions are configurable from the API.
• Brocade translative mode
Registers private storage target devices into the fabric, it can be used in a heterogeneous fabric if
the devices are connected directly to Brocade switches. The devices will be accessible from any
port on the fabric.
Unsupported Brocade Features
In a heterogeneous fabric, the following Brocade optional features are not supported and cannot be
installed on any Brocade switch in the fabric:
• Extended Edge PID format
• Quickloop and QuickLoop Zoning
• Secure Fabric OS
• Timer Server function
• Open E_Port
• Broadcast Zoning
• Management Server Service and FDMI
N
ote
Switches with a condor ASIC do not support translative mode.