Technical data

Fabric OS Administrator’s Guide 2-23
Publication Number: 53-0000518-09
Tracking and Controlling Switch Changes
2
SilkWorm 3016, 3250, 3850, 3900, 4012, and 4100 switches: The following example shows the
command as executed on a SilkWorm 3900 switch. The output is similar on SilkWorm 3016, 3250,
3850, 4012, and 4100 models:
:
SilkWorm 3016: Command output does not include power supplies or fan information.
SilkWorm 12000, 24000, and 48000: Command output includes parameters related to CP blades.
switch:admin> switchstatuspolicyset
To change the overall switch status policy parameters
The current overall switch status policy parameters:
Down Marginal
----------------------------------
FaultyPorts 2 1
MissingSFPs 0 0
PowerSupplies 2 1
Temperatures 2 1
Fans 2 1
PortStatus 0 0
ISLStatus 0 0
Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.
The minimum number of
FaultyPorts contributing to
DOWN status: (0..32) [2] 3
FaultyPorts contributing to
MARGINAL status: (0..32) [1] 2
MissingSFPs contributing to
DOWN status: (0..32) [0]
MissingSFPs contributing to
MARGINAL status: (0..32) [0]
Bad PowerSupplies contributing to
DOWN status: (0..2) [2]
Bad PowerSupplies contributing to
MARGINAL status: (0..2) [1]
Bad Temperatures contributing to
DOWN status: (0..5) [2]
Bad Temperatures contributing to
MARGINAL status: (0..5) [1]
Bad Fans contributing to
DOWN status: (0..6) [2]
Bad Fans contributing to
MARGINAL status: (0..6) [1]
Down PortStatus contributing to
DOWN status: (0..32) [0]
Down PortStatus contributing to
MARGINAL status: (0..32) [0]
down ISLStatus contributing to
DOWN status: (0..32) [0]
down ISLStatus contributing to
MARGINAL status: (0..32) [0]
Policy parameter set has been changed