Technical data

BCSM IN A NUTSHELL 2008
© 2008 Brocade Communications Systems, Incorporated.
Page 22 of 44
SAMPLE FABRIC MERGE ERROR MESSAGES
Domain ID Conflict error message:
2007/12/27-14:38:37, [FABR-1014], 8517, FFDC, ERROR, r3-st02-b20-1, Port 8 Disabled: Insistent
Domain ID 1 could not be obtained. Principal Assigned Domain ID = 2
Even though this message states the Principal Assigned DID is assigned 2, if the persistent DID is set it
cannot change and therefore segments from the fabric
Incompatible Fabric Parameters error message:
2007/12/27-14:45:32, [FABR-1001], 8533,, WARNING, r3-st02-b20-1, port 9, incompatible flow control
parameters (2)
Fabric parameters must match
Zoning Conflict error message:
2007/12/27-14:59:01, [FABR-1001], 8542,, WARNING, r3-st02-b20-1, port 8, Zone Conflict
A merge is not possible if any of the following conditions exist:
Configuration mismatch - Zoning is enabled in both fabrics and the zone configurations that are
enabled are different in each fabric
Type mismatch - The name of a zone object in one fabric is used for a different type of zone
object in the other fabric
Content mismatch - The definition of a zone object in one fabric is different from the definition of
zone object with the same name in the other fabric