Thresholds
20
• Invalid Words (Fabric OS only)
• Link Reset (Fabric OS only)
• Protocol Errors (Fabric OS)
• State Change (Fabric OS only)
NOTE
Fabric OS devices are allowed only 2 defined thresholds (one default and one custom) for each
threshold type and only one of these thresholds can be active on the device.
During the dynamic operation of a Fabric, any port could be any type. For example, a technician
could disconnect a port from a switch and reconnect that port to a storage port, or the port could
change from an E_port to an F_port. Therefore, when calculating the Affected Ports value the
Management application does not look for the current port type, but looks at the policy priority level
in relation to the other policies currently assigned to this switch.
When there are two or more policies on a switch, the total number of Affected Ports may be more
than the total number of ports on the switch (the same port may adopt different policies depending
on changes in the port’s port type).
For default threshold values for Fabric OS devices, refer to Chapter 7 of the Fabric Watch
Administrator's Guide.
C3 Discard Frames threshold
NOTE
This threshold is only available for Fabric OS devices running 6.3 or later.
Use this type of threshold to block a port when a C3 Discard Frames violation meets the Fabric OS
switch threshold. This threshold is only supported on directors, switches, and blades with a 4 Gbps,
8 Gbps, or 16 Gbps ASIC.
• 32-port, 4 Gbps FC Switch
• 64-port, 4 Gbps FC Switch
• 32-port, 4 Gbps FC Interop Switch
• 4 Gbps Router, Extension Switch
• 4 Gbps Extension Switch
• 4 Gbps 32-port Switch
• 8 Gbps 32-port Switch
• 8 Gbps 40-port Switch
• 8 Gbps 24-port Embedded Switch
• 8 Gbps 16-port Embedded Switch
• 8 Gbps 8-FC port, 10 GbE 24-DCB port Switch
• 16 Gbps 24-port Edge switch
• 16 Gbps 48-port Edge switch
• Director Chassis
• 8-slot Backbone Chassis
• 4-slot Backbone Chassis