Technical data

3. Virtual PM&C:Add DSCP and/or CoS Policy.
Using the information from the previous step, use one of the following commands to configure
DSCP and/or CoS marking on the device.
For DSCP and CoS Marking:
# netConfig addQOS --device=<switch_name> vlan=<vlanid> dscp=<dscp value> cos=<cos
value> name=<user defined name>
For DSCP Marking Only:
# netConfig addQOS --device=<switch_name> vlan=<vlanid> dscp=<dscp value>
name=<user defined name>
For CoS Marking Only:
# netConfig addQOS --device=<switch_name> vlan=<vlanid> cos=<cos value>
4. Virtual PM&C: Verify the QoS configuration on the switch
Verify the QoS configuration:
# netConfig getQOS --device=<switch_name> vlan=<vlanid>
Example Output:
# netConfig getQOS --device=6120XG_IOBAY3 vlan=2
Policy: = (
VLAN priorities
VLAN ID Apply rule | DSCP Priority
2 DSCP | 000011 3
)
5. Virtual PM&C: Repeat steps 3-4 for each Policy
Repeat steps 3-4 for each policy that needs to be applied to the switch.
6. Backup the Switch.
Execute the 3.2.5 Backup 6120XG Enclosure Switch procedure.
7. Virtual PM&C: Repeat steps 3-6 for each switch.
Repeat steps 3-6 for each switch identified in step 2.
3.3 Brocade Switch - SwitchConfig Procedures
3.3.1 Configure Brocade Switches
This procedure will configure names, user passwords and NTP settings for Brocade switches and back
up the configuration to the management server hosting PM&C.