53-1002390-08 5 August 2013 Brocade VDX 6710-54 Hardware Reference Manual ®
Copyright © 2011-2013 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Document title Publication number Summary of changes Date Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-05 Rack mount kit information corrected. Added CCC statement. April 2012 Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-06 Management options for the switch have been updated. May 2012 Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-07 Rack mount kit information corrected.
iv Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
Contents About This Document In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . xiii What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Providing power to the switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Verifying operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chapter 3 Brocade VDX 6710-54 Configuration In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Configuration modes for the Brocade VDX 6710-54 . . . . . . . . . . . . 11 Creating a serial connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brocade VDX 6710-54 maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 27 Supported transceivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Installing an SFP+ transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Diagnostic tests and monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 28 Brocade VDX 6710-54 management. . . . . . . . . . . . . . . . . . . . . . . . . 29 Chapter 5 FRU Removal and Replacement Procedures In this chapter . . . . . . . .
Index viii Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
DRAFT: BROCADE CONFIDENTIAL Tables Table 1 Serial cable pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 2 Default administrative account names and passwords . . . . . . . . . . . . . . . . . . . 13 Table 3 Port side LED patterns during normal operation . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 4 Non-port side LED patterns during normal operation . . . . . . . . . . . . . . . . . . . . .
DRAFT: BROCADE CONFIDENTIAL x Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
DRAFT: BROCADE CONFIDENTIAL Figures Figure 1 Port side view of the Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2 Non-port side view of the Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 3 LEDs on the port side of the Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . . . . . 22 Figure 4 LEDs on the non-port side of the Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . .
DRAFT: BROCADE CONFIDENTIAL xii Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Notice to the reader . . . . . . . . . . . . . . . . . . . . .
What’s new in this document The following information has been added: • The LED patterns for the 1 GbE ports have been updated. Refer to “LED patterns.” Document conventions This section describes text formatting conventions and important notice formats used in this document.
Command examples This book describes how to perform configuration tasks using the Network OS command line interface, but does not describe the commands in detail. For complete descriptions of all Network OS commands, including syntax, operand description, and sample output, see the Brocade Network OS Command Reference Guide. Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
Corporation Referenced Trademarks and Products Microsoft Corporation Windows, Windows NT, Internet Explorer Sun Microsystems, Inc. Sun, Solaris Netscape Communications Corporation Netscape Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover Velcro Industries B.V. Velcro Additional information This section lists additional Brocade and industry-specific documentation that you might find helpful. Brocade resources To get up-to-the-minute information, go to http://my.brocade.
• • • • Switch operating system version Error numbers and messages received copy support command output Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2.
xviii Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
Chapter Brocade VDX 6710-54 Introduction 1 In this chapter • Brocade VDX 6710-54 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Views of the Brocade VDX 6710-54 switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Brocade VDX 6710-54 overview The Brocade VDX 6710-54 is a top-of-rack switch designed to accommodate traditional 1 Gigibit Ethernet (GbE) server connections to the Brocade 10 GbE VCS™ technology.
1 Brocade VDX 6710-54 overview • Dual, hot-swappable 250W AC power supplies with three integrated cooling fans each, or dual, hot-swappable 12V 250 W DC power supplies with three integrated cooling fans each • • • • Support for long-range and short-range SFP+ 10 GbE transceivers Support for optical cables and active twin axial (twinax) copper cables Support for direct-attach copper cables Support for inter-switch link (ISL) trunking - Frame-level hardware-based trunking (even distribution of frames ac
Views of the Brocade VDX 6710-54 switch 1 • Support for VLAN, QoS, security, and FCoE port profiles • Virtual Machine-aware network automation Link aggregation • 802.3ad LACP support • Virtual Link Aggregation Group (vLAG) (a LAG that spans multiple physical switches) QoS • 802.1p marking • Eight queues per port • Scheduling: Strict priority (SP), Shaped Deficit Weighted Round-Robin (SDWRR) Management • • • • • • IPv4 or IPv6 management CLI management utilities on Network OS v2.1.
1 Views of the Brocade VDX 6710-54 switch 2 3 4 9 10 11 5 7 6 8 1 1 System power LED 7 1 Gbps Ethernet ports 25 through 36 (25-30 above, 31-36 below) with status LEDs above 2 System status LED 8 1 Gbps Ethernet ports 37 through 48 (37-42 above, 43-48 below) with status LEDs above 3 Serial console port (RJ45) 9 USB port 4 10 Gbps Ethernet SFP+ ports 1 through 6 10 Ethernet management port (RJ45) 5 1 Gbps Ethernet ports 1 through 12 (1-6 above, 7-12 below) with status LEDs above 1
Chapter 2 Brocade VDX 6710-54 Installation In this chapter • Items included with the Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . . . . . . . • Installation and safety considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Standalone installation for a Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . . . • Rack installation for a Brocade VDX 6710-54 . . . . . . . . . . . . . . . . . . . . . . . . . • Providing power to the switch . . . . . . . . . . . . . . . . . . .
2 Installation and safety considerations Electrical considerations To install and operate the switch successfully, ensure compliance with the following requirements: • The primary outlet is correctly wired, protected by a circuit breaker, and grounded in accordance with local electrical codes. • The supply circuit, line fusing, and wire size are adequate, as specified by the electrical rating on the switch nameplate.
Standalone installation for a Brocade VDX 6710-54 2 Cables can be organized and managed in a variety of ways; for example, use cable channels on the sides of the cabinet or patch panels to reduce the potential for tangling the cables. The following list provides some recommendations for cable management: NOTE You should not use tie wraps with optical cables because they are easily overtightened and can damage the optic fibers. Velcro-like wraps are recommended.
2 Rack installation for a Brocade VDX 6710-54 4. Provide power to the switch as described in “Providing power to the switch” on page 8. ATTENTION Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see “Setting the switch IP address” on page 13.
Verifying operation 2 3. The port LEDs should be lit during POST activities. When POST is complete, only the LEDs for ports connected to other devices should be green. See Figure 3 on page 22 for the specific locations of these LEDs. See Table 3 on page 23 and Table 4 on page 25 for more details on the LED patterns.
2 10 Verifying operation Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
Chapter 3 Brocade VDX 6710-54 Configuration In this chapter • Configuration modes for the Brocade VDX 6710-54. . . . . . . . . . . . . . . . . . . • Creating a serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Assigning permanent passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Setting the switch IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Enabling and disabling Brocade VCS mode. . . .
3 Creating a serial connection Creating a serial connection You perform all configuration tasks in this guide using a serial connection from a workstation or terminal to the switch. Complete the following steps to create a serial connection to the switch. 1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation or terminal device.
Assigning permanent passwords 3 Assigning permanent passwords When you log in for the first time, Brocade recommends that you change the passwords for the default accounts. The factory-configured default accounts on the switch are admin, user, and root. Use the default administrative account as shown in Table 2 to log in to the switch for the first time and to perform the basic configuration tasks. The root account is reserved for development and manufacturing.
3 Setting the switch IP address Using DHCP to set the IP address When using DHCP, the Brocade VDX 6710-54 obtains its IP address, subnet mask, and default gateway address from the DHCP server. The DHCP client can only connect to a DHCP server that is on the same subnet as the switch. If your DHCP server is not on the same subnet as the Brocade VDX 6710-54, use a static IP address. To set an IPv4 IP address using DHCP, complete the following steps. 1. Log in to the switch using the admin account. 2.
Enabling and disabling Brocade VCS mode 3 no ipv6 address autoconfig ! Setting stateless IPv6 autoconfiguration IPv6 allows assignment of multiple IP addresses to each network interface. Each interface is configured with a link local address in almost all cases, but this address is only accessible from other hosts on the same network. To provide for wider accessibility, interfaces are typically configured with at least one additional global scope IPv6 address.
3 Enabling and disabling Brocade VCS mode Enabling VCS mode Perform the following steps to enable VCS mode. 1. Log in to the switch using an account that has the admin role. 2. Enter the vcs enable command, including the RBridge parameter, as in the following example. vcs rbridge-id 1 enable The switch reboots when you confirm that you want to enable VCS mode.
Setting the date and time 3 Setting the date and time The Brocade VDX 6710-54 maintains the current date and time inside a battery-backed real-time clock (RTC) circuit. Date and time are used for logging events. Switch operation does not depend on the date and time; a Brocade VDX 6710-54 with an incorrect date and time value functions properly. Because the date and time are used for logging, error detection, and troubleshooting, you should set them correctly.
3 Setting the date and time Synchronizing local time using NTP Perform the following steps to synchronize the local time using NTP. 1. Log in to the switch using the default password (the default password is password). 2. Enter the ntp server "" command, where is the IP address of the first NTP server in IPv4 format, which the switch must be able to access. The variable is optional.
Connecting network devices 3 Use the clock TimeZone command to set the time zone. 1. Connect to the switch and log in using an account assigned to the admin role. 2. Enter the clock TimeZone / command.
3 Creating Brocade inter-switch link trunks Creating Brocade inter-switch link trunks In VCS mode, unless specifically disabled, inter-switch link (ISL) trunking between adjacent switches is automatic. All ports must be in the same port group and must be configured at the same speed. There is a limit of eight ports per trunk group. No separate licensing is required. For more information about Brocade trunks, see the Brocade Network OS Administrator’s Guide.
Chapter 4 Brocade VDX 6710-54 Operation In this chapter • Powering on the Brocade VDX 6710-54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . • LED activity interpretation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • POST and boot specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Interpreting POST results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Brocade VDX 6710-54 maintenance .
4 LED activity interpretation • One bicolor system status LED (green and amber) on the port side. • One power status LED (green) on the port side. • Two Ethernet management port LEDs (green) for the Ethernet management port. The two LEDs show the status of the port link and the port activity. • One bicolor port status LED (green and amber) for each port on the switch.
LED activity interpretation 1 Power supply and fan assembly #2 status LED FIGURE 4 2 4 Power supply and fan assembly #1 status LED LEDs on the non-port side of the Brocade VDX 6710-54 LED patterns Table 3 describes the port side LEDs and their behaviors. TABLE 3 Port side LED patterns during normal operation LED name LED color Status of hardware Recommended action System power (one LED [green]) Off (no light) System is off or there is an internal power supply failure.
4 LED activity interpretation TABLE 3 Port side LED patterns during normal operation (Continued) LED name LED color Status of hardware Recommended action Optical media port status (one bicolor LED [green and amber] for each 10 GbE port) Off (no light) No light or signal carrier on the media interface. Verify that the transceiver is installed correctly and that the cable is connected correctly. Steady green Link is present. No action required.
POST and boot specifications 4 Table 4 describes the LEDs on the non-port side of the switches. TABLE 4 Non-port side LED patterns during normal operation LED name LED color Status of hardware Recommended action Power supply and fan assembly status (one LED [green] per power supply and fan assembly) Off (no light) Assembly is not receiving power or is turned off. Verify the assembly is on and seated and the power cord is connected to a functioning power source.
4 Interpreting POST results • Initializes hardware. • Runs diagnostic tests on several functions, including circuitry, port functionality, memory, statistics counters, and serialization. Boot In addition to POST, boot includes the following tasks after POST is complete: • Performs universal port configuration. • Initializes links. • Analyzes fabric. If any ports are connected to other switches, the switch participates in a fabric configuration. • Obtains a domain ID and assigns port addresses.
Brocade VDX 6710-54 maintenance 4 Brocade VDX 6710-54 maintenance The Brocade VDX 6710-54 is designed for high availability and low failure; it does not require any regular physical maintenance. The SFP+ optical transceivers and diagnostic tests are described in the following sections. Supported transceivers The Brocade VDX 6710-54 supports only Brocade-branded SFP+ optical transceivers for its 10 Gbps DCB ports. The optical SFP+ transceivers support both Short Reach (SR) and Long Reach (LR) modules.
4 Brocade VDX 6710-54 maintenance ! FIGURE 5 Installing an SFP or SFP+ transceiver in the upper row of port slots Diagnostic tests and monitoring In addition to POST, the Network OS includes diagnostic tests to help you troubleshoot the hardware and firmware. This includes tests of internal connections and circuitry, fixed media, and the transceivers and cables in use.
Brocade VDX 6710-54 management 4 Brocade VDX 6710-54 management You can use the management functions built into the Brocade VDX 6710-54 to monitor the fabric topology, port status, physical status, and other information to help you analyze switch performance and to accelerate system debugging. For information about upgrading the version of Network OS installed on your switch, see the Brocade Network OS Administrator’s Guide.
4 30 Brocade VDX 6710-54 management Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
Chapter FRU Removal and Replacement Procedures 5 In this chapter • Before beginning the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 • Replacing a combined FRU in a Brocade VDX 6710-54 . . . . . . . . . . . . . . . . 32 Before beginning the installation The field-replaceable units (FRUs) in the Brocade VDX 6710-54 switch can be removed and replaced without special tools.
5 Replacing a combined FRU in a Brocade VDX 6710-54 E AIRFLOW FIGURE 6 AIRFLOW Examples of airflow symbols The green E symbol indicates an exhaust FRU. This unit pulls air in from the port side of the switch and exhausts it out the non-port side. This is called front-to-back airflow or forward airflow. This symbol should appear on FRUs with part numbers ending with -F. The orange I symbol indicates an intake FRU.
Replacing a combined FRU in a Brocade VDX 6710-54 2 1 3 4 5 6 8 7 1 Power supply and fan assembly #2 5 Handle 2 Status LED 6 Airflow label 3 On/off switch 7 Captive screw 4 DC power cord receptacle 8 Power supply and fan assembly #1 FIGURE 8 5 Brocade VDX 6710-54 DC power supply and fan assemblies on the non-port side ATTENTION Maintain all power supply and fan assemblies in operational condition to provide redundancy.
5 Replacing a combined FRU in a Brocade VDX 6710-54 TABLE 6 Brocade VDX 6710-54 LED behavior, descriptions, and required actions LED color and behavior Description Action required Steady green Assembly is operating normally. No action required. Blinking green One of the following may have occurred: • Mismatched airflow on power supply and fan assembly • • • • The power supply and fan assembly was disabled by the user.
Replacing a combined FRU in a Brocade VDX 6710-54 a. 5 Orient the new power supply and fan assembly with the captive screw on the right as shown in Figure 9 or Figure 10. CAUTION Do not force the installation. If the power supply and fan assembly does not slide in easily, ensure that it is correctly oriented before continuing. b. Gently push the power supply and fan assembly into the chassis until it is firmly seated. c.
5 Replacing a combined FRU in a Brocade VDX 6710-54 1 2 4 3 P/N: xxxxxxx-xx 1 Brocade VDX 6710-54 chassis 3 Label with part number 2 DC power supply and fan assembly 4 Captive screw FIGURE 10 Orientation of the DC power supply and fan assembly in the Brocade VDX 6710-54 5. Verify that the power supply and fan assembly status LED is steady green to indicate normal operation (see Table 6 for more LED information).
Appendix A Brocade VDX 6710-54 Specifications In this appendix • Weight and physical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Facility requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • Environmental requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A Power supply specifications TABLE 8 Facility requirements Type Requirements Electrical • • Primary AC input 85-265 VAC nominal, 47-63 Hz; switch autosenses input voltage Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate • Circuit protected by a circuit breaker and grounded in accordance with local electrical codes Refer to Table 9 on page 38 for complete power supply specifications.
Environmental requirements A Environmental requirements Table 10 lists the acceptable environmental ranges for both operating and nonoperating (such as during transportation or storage) conditions.
A Data transmission ranges Data transmission ranges Table 12 provides the data transmission ranges for different cable types and port speeds for all ports. TABLE 12 Data transmission ranges Cable and connector type Connector Cable Distance Active copper (Laserwire) SFP copper Plastic optical fiber Up to 20 m (65.62 ft) [1 m (3.28 ft), 3 m (9.84 ft), and 5 m (16.40 ft) supported] Active optical cable SFP+ optical Plastic optical fiber 10m (32.81 ft) and 20m (65.
Regulatory compliance A • “Canadian requirements” • “China statement” • “Laser compliance” FCC warning (US only) This equipment has been tested and complies with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
A Regulatory compliance Power cords (Japan DENAN) BSMI statement (Taiwan) Warning: This is Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. CE statement ATTENTION This is a Class A product.
Regulatory compliance A China statement China-CCC Warning statements 在维修的时候一定要断开所有电源 (English translation“disconnect all power sources before service”) For non tropical use: 汉文 “仅适用于非热带气候条件下安全使用。” 藏文 安全 说明 和标 记 蒙古 文 壮文 Dan hab yungh youq gij dienheiq diuzgen mbouj dwg diegndat haenx ancienz sawjyungh. 维文 For altitude 2000 meter and below: 汉文 仅适用于海拔2000m以下地区安全使用。 藏文 安全 说明 和标 记 蒙古 文 壮文 Dan hab yungh youq gij digih haijbaz 2000m doxroengz haenx ancienz sawjyungh.
A Electrical cautions Laser compliance This equipment contains Class 1 laser products and complies with FDA Radiation Performance Standards, 21 CFR Subchapter I and the international laser safety standard IEC 825-2. ATTENTION Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 825-2.
Electrical cautions A DC-DC power source cautions Each statement below appears in English, German, French, and Spanish, respectively. A caution calls your attention to a possible hazard that can damage equipment. "Vorsicht" weist auf eine mögliche Beschädigung des Geräts hin. Sie finden die folgenden Vorsichtshinweise in diesem Handbuch. Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équipement. Ci-dessous, vous trouverez les mises en garde utilisées dans ce manuel.
A Electrical cautions CAUTION For the DC input circuit to the system of a VDX 6710/6720/6730, make sure there is a UL-Listed 15 amp circuit breaker, minimum 48Vdc, double pole, on the input lugs to the power supply. The input wiring for connection to the product should be Listed copper wire, 14 AWG, marked VW-1, and rated minimum 90°C.
Regulatory certifications A CAUTION For a DC system, use a grounding wire of at least 14 American Wire Gauge (AWG). The 14 AWG wire should be attached to an agency-approved crimp connector (Tyco 34120 or certified Lug), crimped with the proper crimping tool and attached to the protective grounding lug, using a size #6-32 screw and a star washer, on the chassis with the other end to building ground. Each DC-DC power supply must have a separate grounding cable.
A Environmental regulation compliance 䙉ᅜ⦃๗⊩㾘 Ё RoHS ᴀ㡖Ёࣙⱘݙᆍ䛑䙉ᅜњЁढҎ⇥݅lj⬉ᄤֵᙃѻક∵ᶧࠊㅵ⧚ࡲ⊩NJⱘ 㽕∖DŽ Environmental protection use period (EPUP) disclaimer In no event do the EPUP logos shown on the product and FRUs alter or expand that warranty that Brocade provides with respect to its products as set forth in the applicable contract between Brocade and its customer.
Environmental regulation compliance A TS/HS dual language sheet In accordance with China's Management Measures on the Control of Pollution caused by Electronic Information products (Decree No. 39 by the Ministry of Information Industry), the information in Table 15 is provided regarding the names and concentration level of Hazardous substances (HS) which may be contained in this product.
A 50 Environmental regulation compliance Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08
Index A accessing NTP server, 18 airflow reversible, 1 symbols, 31 warning, 31 B boot, 26 boot flash memory, 40 Brocade Network Advisor, 29 BSMI compliance statement (Taiwan), 42 C cable bending limit, 6 cable management, 6 Canadian complaiance statement, 42 CE compliance statement, 42 China (CCC) compliance statement, 43 China RoHS, 47 CLI, 29 clock set command, 18 clock timezone command, 17, 19 Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08 command clock set, 18 clock timezone, 17, 19 co
D I data transmission ranges, 40 diagnostic tests, 28 distributed intelligence, 11 installation cabinet install, 8 items required, 7 options, 5 safety considerations, 5 standalone Brocade VDX 6710-54, 7 installing SFP or SFP+, 27 interface management command, 14 interpreting POST results, 26 inter-switch links, 20 ip address command, 14 ip address dhcp command, 14 ip gateway-address command, 14 ipv6 address autoconfig command, 15 ISL trunking, 20 items included with the Brocade VDX 6710-54, 5 E electric
N network connectivity, testing, 19 no diag post command, 25 no ipv6 address autoconfig command, 15 no ntp server command, 18 no vcs enable command, 16 NTP server access, 18 ntp server command, 17, 18 P physical dimensions, 37 platform components, 1 POST, 25 POST and boot specifications, 25 power cord statement (Japan DENAN), 42 power off, 21 power supplies, 4 specifications, 38 power-on, self-test see POST R rack considerations, 6 regulatory certifications, 47 regulatory compliance, 40 removal and replac
V VCCI compliance statement (Japan), 41 VCS, 1 vcs enable command, 16 VCS mode, 11 enable and disable, 15 VCS trunking, 20 vcs vcs-id command, 16 verifying operation, 8 virtual cluster switching see VCS W weight, 37 54 Brocade VDX 6710-54 Hardware Reference Manual 53-1002390-08