Technical data

Fabric OS v6.1.0_del1 Release Notes, v1.0 Page 11 of 13
Open Defects in Fabric OS v6.1.0_ del1
This section lists defects with Critical, High and Medium technical severity that are open in Fabric OS v6.1.0_del1
as of the time of release. While these defects are still formally “open,” they are unlikely to impede Brocade
customers in their deployment of the Brocade M5424 and have been deferred for resolution in a later release.
None of these defects have the requisite combination of probability and severity to cause significant concern to
Brocade customers.
Note that when a workaround to an issue is available, it is noted.
Defect ID
Technical
Severity
Summary of OPEN Defects in Fabric OS v6.1.0_del1
DEFECT000224460 High Summary: Host may lose targets on edge AG in cascaded setup when failover
from core-AG to another core-AG connected to different edge fabric switches.
Symptom: Host would lose targets on edge in cascaded setup when F-port is
failed over from one N-port connected on one core-AG to another N-port
connected to another core-AG.
Workaround: Disable/enable the N-port
Customer Impact: Workaround available
Feature: Access Gateway Services
Function: CLI
Reported in Release: FOS6.1.0_del
DEFECT000218368 Medium Summary: AG N_port connected to embedded switch in inter-op mode 2 could
not restart traffic after switchdisable/enable followed by
configupload/download.
Symptom: Unable to restart traffic.
Customer Impact: Unlikely User Scenario
Feature: Access Gateway Services
Function: CLI
Reported in Release: FOS6.1.0_del