4 Brocade SAN Switch Module: Installation Guide
Table 1. Fibre Channel switch-module specifications .
Fibre Channel switch-module
standards and protocols:
Fibre Channel standards:
FC-AL ANSI X3.272:
FC-AL-2 NCIT S 332:
•FC-FLA NCIT S
TR-20:
FC-GS-3 NCITS 348-2000
Rev 7.01
FC-FG ANSI X3.289:
FC-FS Rev 1.7
FC-PH ANSI X3.230:
FC-PH-2 ANSI X3.297:
FC-PH-3 ANSI X3.303:
FC-PLDA NCIT S TR-19:
FC-SW-2 Rev 5.3
FC-VI Rev 1.61
IPFC RFC 2625
SANmark compliance
SCD-3001 v2a1...
FC-MI, Rev 1.92
FC-SB-3 ANSI/INCITS
374:2003
FC-BB-2 Rev 5.3
Fibre Channel switch-module
standards and protocols
(continued):
Fibre Channel protocols:
Fibre Channel service
classes: Class 2 and
class 3.
Operation modes: Fibre
Channel class 2 and class
3, connectionless.
External port type:
F_port.
FL_port.
E_port.
Self-discovery based
on switch type U_port,
an optional port type.
Internal port type: 2 Gbps
is the default setting.
Port characteristics:
External ports are
automatically detected and
self-configuring.
Number of Fibre Channel
ports: Two external ports
and 14 internal ports.
Scalability: 239 switches
maximum depending on
your configuration.
Fibre Channel switch-module
standards and protocols
(continued):
Fibre Channel protocols
(continued):
Buffer credits: 16 buffer
credits per port
Media type: Small form-
factor pluggable (SFP)
module
Fabric port speed: 1.0625
or 2.125 Gbps (gigabits
per second)
Maximum frame size: 2148
bytes (2112-byte payload)
System processor:
PPC405GP
Fabric latency: Less than
2.1 µsec from any port to
any port at 2 Gbps, cut-
through routing
Fabric point-to-point
bandwidth: 2 Gbps or 4
Gbps at full duplex
Fabric aggregate
bandwidth: 64 Gbps if all
16 ports are running 2
Gbps at full duplex
Nonblocking architecture
shared-memory switch to
prevent latency