Vacuum Cleaner User Manual
5
Switch maintainability:
• Diagnosis: Power-on self-
test (POST) is performed
on all functional
components except the
SFP module. Port
operational tests include
internal, external, and
online tests.
• User interface: Light-
emitting diode (LED)
indicators.
Fabric management:
• Management methods:
— Web interface through
Advanced Web Tools
— Command-line
interface (CLI) through
Telnet program
— Application program
interface (API)
• Brocade Fabric Manager
for Intel Blade Server
chassis Advanced Feature
Options:
Provides Java
*
-based
application program to
help manage the storage
area network (SAN) fabric
• Management information
base (MIB)
• Switch simple network
management protocol
(SNMP) agent:
Enables a network
management workstation
to receive configuration
values, traffic information,
and Fibre Channel failure
data through SNMP and
the Ethernet interface
Dimensions:
• Width: 112 mm (4.41 in.)
• Height: 29 mm (1.14 in.)
• Depth: 260.3 mm
(10.25 in.)
• Weight: Approximately
.91 kg (2 lb)
Environmental:
• Temperature and altitude:
— Operating:
–10° C to 52° C
(50° F to 125.6° F)
at an altitude of
0 to 914 m
(0 to 3 000 ft)
–10° C to 49° C
(50° F to 120.2° F) at
an altitude of
0 to 3 000 m
(0 to 10 000 ft)
— Non-operating:
-40° C to 65° C
(-40° F to 149° F) at an
altitude of
0 to 12 000 m
(0 to 39 370 ft)
•Humidity:
— Operating: 8% to 80%,
noncondensing
— Non-operating: 5% to
80%, noncondensing
Switch regulatory
certifications:
• Electrical requirements:
— Power source loading:
3.75 amps maximum at
12 V dc
— Approximate heat
output in British
thermal units (Btu) per
hour: 85.3 Btu (25
watts)
— Operating voltage:
12 V dc
— Circuit protection:
Internally fused with
over-current protection
• Safety standards:
— As a listed accessory
by UL (USA)
— As a component by
TUV
— For use only in Intel
Blade Server chassis
Table 1. Fibre Channel switch-module specifications (continued).