5
Switch maintainability:
Diagnosis: Power-on self-
test (POST) is performed
on all functional
components except the
SFP module. Port
operational tests include
internal, external, and
online tests.
User interface: Light-
emitting diode (LED)
indicators.
Fabric management:
Management methods:
Web interface through
Advanced Web Tools
Command-line
interface (CLI) through
Telnet program
Application program
interface (API)
Brocade Fabric Manager
for Intel Blade Server
chassis Advanced Feature
Options:
Provides Java
*
-based
application program to
help manage the storage
area network (SAN) fabric
Management information
base (MIB)
Switch simple network
management protocol
(SNMP) agent:
Enables a network
management workstation
to receive configuration
values, traffic information,
and Fibre Channel failure
data through SNMP and
the Ethernet interface
Dimensions:
Width: 112 mm (4.41 in.)
Height: 29 mm (1.14 in.)
Depth: 260.3 mm
(10.25 in.)
Weight: Approximately
.91 kg (2 lb)
Environmental:
Temperature and altitude:
Operating:
–10° C to 52° C
(50° F to 125.6° F)
at an altitude of
0 to 914 m
(0 to 3 000 ft)
–10° C to 49° C
(50° F to 120.2° F) at
an altitude of
0 to 3 000 m
(0 to 10 000 ft)
Non-operating:
-40° C to 65° C
(-40° F to 149° F) at an
altitude of
0 to 12 000 m
(0 to 39 370 ft)
•Humidity:
Operating: 8% to 80%,
noncondensing
Non-operating: 5% to
80%, noncondensing
Switch regulatory
certifications:
Electrical requirements:
Power source loading:
3.75 amps maximum at
12 V dc
Approximate heat
output in British
thermal units (Btu) per
hour: 85.3 Btu (25
watts)
Operating voltage:
12 V dc
Circuit protection:
Internally fused with
over-current protection
Safety standards:
As a listed accessory
by UL (USA)
As a component by
TUV
For use only in Intel
Blade Server chassis
Table 1. Fibre Channel switch-module specifications (continued).