Technical data

44 ServerIron ADX Administration Guide
53-1002434-01
Power budgeting on the ServerIron ADX
1
Syntax: show feature
Power budgeting on the ServerIron ADX
The following power budged it available on the ServerIron ADX models as shown in the following:
ServerIron ADX 1000 – A maximum of 2 power supplies are available. Each power supply is
rated at 504 W. A single power supply will meet the demands of a fully operating ServerIron
ADX 1000. The ServerIron ADX 1000 is not subject to power budgeting.
ServerIron ADX 4000 – A maximum of 2 power supplies are available. At least one power
supply must be connected and operating in a fully-loaded ServerIron ADX 4000 chassis.
ServerIron ADX 8000 – A maximum of 4 power supplies are available. At least two power
supplies must be connected and operating in a fully-loaded ServerIron ADX 8000 chassis.
Table 1 describes the amount of power in Watts required to bring-up the components of a
ServerIron ADX 4000 or ServerIron ADX 8000 system
.
Operation of power budgeting
With ServerIron ADX 4000 and ServerIron ADX 4000 and ServerIron ADX 8000, the system follows
a procedure for powering-up various components. If the power demands of a component exceed
the power budget of the ServerIron ADX system, the component will not be brought up and a
message will be sent to the SYSLOG. The sequence for power-up is described in the following steps.
ServerIronADX1/1#show feature
l7 switching : OFF
sFlow : OFF
NAT : ON
TCS/FW : OFF
ACL : OFF
inbound ACL : OFF
GSLB controller : ON
SYN proxy : ON
SYN defence : OFF
SLB only : OFF
TABLE 1 ServerIron ADX start-up power requirements
ServerIron ADX
system component
Power requirements forsStart-up
Interface Module 74 W
Switch Fabric Module 69 W
Application Switch Module 330 W
Management Module 140 W
Fans at 100% RPM 84 W