Technical data
ServerIron ADX Administration Guide 75
53-1002434-01
Using Syslog
1
Notification L4 server <ip-addr> <name> is up Indicates that a real server or cache server has come up.
The <ip-addr> is the server’s IP address.
The <name> is the name of the server.
Notification L4 server <ip-addr> <name> is down due
to <reason>
Indicates that a real server or cache server has gone
down.
The <ip-addr> is the server’s IP address.
The <name> is the name of the server.
The <reason> is the reason the ServerIron ADX changed
the port’s state to down. The <reason> can be one of the
following:
• healthck – The port failed a health check. This
applies to standard health checks and Boolean
health checks.
• reassign – The reassign threshold was reached.
• server-down – The server failed the Layer 3 health
check when you bound the real server to the VIP.
• MAC-delete – The server’s MAC address was
deleted from the ServerIron ADX MAC table.
• graceful-shutdown – The server was gracefully shut
down.
• mp-port-state-change – The port was brought down
on the BP managing the real server, in response to
a message from the MP CPU that the port is down.
NOTE: This value applies only to ServerIron ADX Chassis
devices.
• other – The port was brought down by another
application (by something other than the ServerIron
ADX.)
• unknown – The port was brought down by a reason
other than one of those listed above.
Notification L4 server <ip-addr> <name> TCP port
<tcp-port-num> is up
Indicates that a real server’s or cache server’s TCP port
has come up.
The <ip-addr> is the server’s IP address.
The <name> is the name of the server.
The <tcp-port-num> is the TCP port number.
Notification L4 server <ip-addr> <name> TCP port
<tcp-port-num> is down
Indicates that a real server’s or cache server’s TCP port
has gone down.
The <ip-addr> is the server’s IP address.
The <name> is the name of the server.
The <tcp-port-num> is the TCP port number.
Notification L4 switch changed state from active to
standby
The ServerIron ADX is an active-standby configuration
and has changed from the active to the standby state.
Notification L4 switch changed state from standby to
active
The ServerIron ADX is an active-standby configuration
and has changed from the standby to the active state.
Notification L4 gslb connection to site <name>
ServerIronADX <ip-addr> <name> is up
The GSLB protocol connection from this GSLB ServerIron
ADX to a remote site ServerIron ADX has come up.
The first <name> the site name.
The <ip-addr> and <name> are the site ServerIron ADX’s
management IP address and name.
TABLE 4 Brocade Syslog messages (Continued)
Message
Level
Message Format Explanation