Technical data
76 ServerIron ADX Administration Guide
53-1002434-01
Using Syslog
1
Notification L4 gslb connection to site <name>
ServerIronADX <ip-addr> <name> is
down
The GSLB protocol connection from this GSLB ServerIron
ADX to a remote site ServerIron ADX went down.
The first <name> the site name.
The <ip-addr> and <name> are the site ServerIron ADX’s
management IP address and name.
Notification L4 gslb connection to gslb ServerIronADX
<ip-addr> is up
The GSLB protocol connection from this site ServerIron
ADX to a remote GSLB ServerIron ADX has come up.
The <ip-addr> is the GSLB ServerIron ADX’s
management IP address.
Notification L4 gslb connection to gslb ServerIronADX
<ip-addr> is down
The GSLB protocol connection from this site ServerIron
ADX to a remote GSLB ServerIron ADX has gone down.
The <ip-addr> is the GSLB ServerIron ADX’s
management IP address.
Notification L4 gslb health-check <ip-addr> of
<zone> status changed to up
The IP address belonging to a domain name for which
the ServerIron ADX is providing GSLB has come up.
The <ip-addr> is the IP address in the DNS reply.
The <zone> is the zone name.
Notification L4 gslb health-check <ip-addr> of
<zone> status changed to down
The IP address belonging to a domain name for which
the ServerIron ADX is providing GSLB has gone down.
The <ip-addr> is the IP address in the DNS reply.
The <zone> is the zone name.
Notification L4 gslb health-check <ip-addr> of
<zone> port <tcp/udp-port> is up
An application port in a domain on the site IP address
passed its Layer 4 TCP or UDP health check.
The <ip-addr> is the IP address in the DNS reply.
The <zone> is the zone name.
The <tcp/udp-port> is the application port.
Notification L4 gslb health-check <ip-addr> of
<zone> port <tcp/udp-port> is down
An application port in a domain on the site IP address
failed its Layer 4 TCP or UDP health check.
The <ip-addr> is the IP address in the DNS reply.
The <zone> is the zone name.
The <tcp/udp-port> is the application port.
Informatio
nal
Cold start The device has been powered on.
Informatio
nal
Warm start The system software (flash code) has been reloaded.
Informatio
nal
<user-name> login to USER EXEC mode A user has logged into the USER EXEC mode of the CLI.
The <user-name> is the user name.
Informatio
nal
<user-name> logout from USER EXEC
mode
A user has logged out of the USER EXEC mode of the CLI.
The <user-name> is the user name.
Informatio
nal
<user-name> login to PRIVILEGED mode A user has logged into the Privileged EXEC mode of the
CLI.
The <user-name> is the user name.
Informatio
nal
<user-name> logout from PRIVILEGED
mode
A user has logged out of Privileged EXEC mode of the
CLI.
The <user-name> is the user name.
TABLE 4 Brocade Syslog messages (Continued)
Message
Level
Message Format Explanation