Technical data

82 ServerIron ADX Administration Guide
53-1002434-01
Additional system management functions
1
Syntax: show clock
showing with RTC...
08:23:42, GMT+00, Mon Sep 12 2011
For more information, refer to the marketing advisory.
Changing the shutdown temperature
You can change the shutdown temperature of a module containing a temperature sensor. If the
temperature matches or exceeds the shutdown temperature, the software sends a Syslog message
to the Syslog buffer and also to the Syslog server if configured. The software also sends an SNMP
trap to the SNMP trap receiver, if you have configured the device to use one.
If the temperature equals or exceeds the shutdown temperature for five consecutive polls of the
temperature by the software, the software shuts down the module to prevent damage.
To change the temperature for a management module, enter the following command.
ServerIronADX# temperature shutdown mgmt 65
Syntax: temperature shutdown mgmt <value>
The <value> parameter can be 0 – 125 degrees celsius. The default is 100.
To change the temperature for a line card, enter the following command.
ServerIronADX# temperature shutdown lc 65
Syntax: temperature shutdown lc <value>
The <value> parameter can be 0 – 75 degrees celsius. The default is 75.
NOTE
The lc option is required only for chassis type model such as ADX4000, ADX10000, and so on.
NOTE
if you change the temperature, you must execute “write memory” to save the changed temperature.
Changing the temperature warning
You can change the warning temperature of a module containing a temperature sensor. If the
temperature of the module reaches the warning value, the software sends a Syslog message to the
Syslog buffer and also to the Syslog server, if configured. In addition, the software sends an SNMP
trap to the SNMP trap receiver, if you have configured the device to use one.
NOTE
You cannot set the warning temperature to a value higher than the shutdown temperature.
To change the warning temperature for a management module, enter the following command.
ServerIronADX# temperature warning mgmt 55
Syntax: temperature warning mgmt <value>
The <value> parameter can be 0 – 125. The default is 85.
To change the warning temperature for a line card, enter the following command.
ServerIronADX# temperature warning lc 55