OpenScript
7
The Script Profiles - new page tab is displayed, as shown in Figure 79.
FIGURE 79 Configuring script profile
4. Provide the following information:
Profile name: Enter the name of the script profile that you want to create or update.
Memory Limit (bytes): Enter the memory limit for any script that is bound to the script
profile. The range is from 1 through 1073741824 bytes. The default value is 1,048,576
bytes.
Memory High Watermark: Enter the script memory high-watermark percentage, so that
when the high-water percentage reaches, a system log message is generated and the
script resets the new connection on the device. The range is from 1 through 100
percentage. The default value is 90 percentage.
Timeout Seconds: Enter the watchdog time for the script in milliseconds. The range is from
1 through 1000 milliseconds. The default value is 200 milliseconds.
Data Collection Limit: Enter the maximum data collection limit for the script in bytes. The
range is from 1 through 4,294,967,296. The default value is 1000000 bytes.
Debug: Select the Enable check box to allow debugging for the script. When you enable the
debug flag, the debug information is printed at the console.
Restart Limit: Enter the maximum number of times that the script will restart.
Output Destination: Select one of the following from the list.
Console—Sets the script to print its output to the console. By default, console is set to
be the output destination.
Syslog—Sets the script to print its output to the syslog.
None—Disables the script from printing.
5. Click Apply to save your entries.
Click Reset to revert the configuration to the previous configured values.