Configuration Guide (Supporting R2.2.0.0) Owner's manual

278 Brocade 6910 Ethernet Access Switch Configuration Guide
53-1002651-02
12
Interface Commands
Vendor OUI : 00-05-1E
Vendor Name : BROCADE
Vendor PN : 33210-100
Vendor Rev : A
Vendor SN : TAF11119000075U
Date Code : 11-05-06
DDM Info
Temperature : 31.62 degree C
Vcc : 3.27 V
Bias Current : 5.48 mA
TX Power : -5.45 dBm
RX Power : -33.01 dBm
DDM Thresholds
Low Alarm Low Warning High Warning High Alarm
----------- ------------ ------------ ------------ ------------
Temperature(Celsius) -123.00 0.00 70.00 75.00
Voltage(Volts) 3.10 3.15 3.45 3.50
Current(mA) 6.00 7.00 90.00 100.00
TxPower(dBm) -12.00 -11.50 -9.50 -9.00
RxPower(dBm) -21.50 -21.00 -3.50 -3.00
Console#
Cable Diagnostics
test cable-diagnostics
This command performs cable diagnostics on the specified port to diagnose any cable faults
(short, open, etc.) and report the cable length.
Syntax
test cable-diagnostics interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-12)
Command Mode
Privileged Exec
Command Usage
Cable diagnostics are performed using Digital Signal Processing (DSP) test methods. DSP
analyses the cable by sending a pulsed signal into the cable, and then examining the reflection
of that pulse.
This cable test is only accurate for cables 7 - 140 meters long.
The test takes approximately 5 seconds. The switch displays the results of the test immediately
upon completion, including common cable failures, as well as the status and approximate
length of each cable pair.
Potential conditions which may be listed by the diagnostics include:
OK: Correctly terminated pair
Open: Open pair, no link partner