Configuration Guide User guide

BigIron RX Series Configuration Guide 1389
53-1002484-04
Syslog messages
A
Syslog messages
Table 242 lists all of the Syslog messages. The messages are listed by message level, in the
following order:
Emergencies (none)
Alerts
Critical
Errors
Warnings
Notifications
Informational
Debugging
TABLE 242 Brocade Syslog messages
Message level Message Explanation
Alert Power supply <num>, <location>, failed A power supply has failed.
The
<num> is the power supply number.
The
<location> describes where the failed
power supply is in the device.
Alert Fan
<num>, <location>, failed A fan has failed.
The
<num> is the power supply number.
The
<location> describes where the failed
power supply is in the device.
Alert Management module at slot
<slot-num>
state changed from
<module-state> to
<module-state>.
Indicates a state change in a management
module.
The
<slot-num> indicates the device slot
containing the module.
The
<module-state> can be one of the
following:
active
standby
crashed
coming-up
unknown
Alert Temperature
<degrees> C degrees, warning
level
<warn-degrees> C degrees, shutdown
level
<shutdown-degrees> C degrees
Indicates an overtemperature condition on
the active module.
The
<degrees> value indicates the
temperature of the module.
The
<warn-degrees> value is the warning
threshold temperature configured for the
module.
The
<shutdown-degrees> value is the
shutdown temperature configured for the
module.
Alert
<num-modules> modules and 1 power
supply, need more power supply!!
Indicates that the device needs more power
supplies to run the modules in the device.
The
<num-modules> parameter indicates the
number of modules in the device.
Alert OSPF Memory Overflow OSPF has run out of memory.