Reference (Supporting Fabric OS v7.3.0) Owner manual

Table Of Contents
308 Fabric OS Command Reference
53-1003131-01
fcoe
2
Index Slot Port Address Media Speed State Proto
============================================================
192 8 0 02c000 -- 10G Online FCoE VF-Port 0 VN-Port(s)
193 8 1 02c100 -- 10G Online FCoE VF-Port 0 VN-Port(s)
194 8 2 02c200 -- 10G Online FCoE VF-Port 0 VN-Port(s)
195 8 3 02c300 -- 10G Online FCoE VF-Port 0 VN-Port(s)
196 8 4 02c400 -- 10G Online FCoE VF-Port 0 VN-Port(s)
197 8 5 02c500 -- 10G Online FCoE VF-Port 0 VN-Port(s)
198 8 6 02c600 -- 10G Online FCoE VF-Port 0 VN-Port(s)
199 8 7 02c700 -- 10G Online FCoE VF-Port 0 VN-Port(s)
200 8 8 02c800 -- 10G Online FCoE VF-Port 0 VN-Port(s)
201 8 9 02c900 -- 10G Online FCoE VF-Port 0 VN-Port(s)
202 8 10 02ca00 -- 10G Online FCoE VF-Port 0 VN-Port(s)
203 8 11 02cb00 -- 10G Online FCoE VF-Port 0 VN-Port(s)
204 8 12 02cc00 -- 10G Online FCoE VF-Port 0 VN-Port(s)
205 8 13 02cd00 -- 10G Online FCoE VF-Port 0 VN-Port(s)
206 8 14 02ce00 -- 10G Online FCoE VF-Port 0 VN-Port(s)
207 8 15 02cf00 -- 10G Online FCoE VF-Port 0 VN-Port(s)
208 8 16 02d000 -- 10G Online FCoE VF-Port 0 VN-Port(s)
209 8 17 02d100 -- 10G Online FCoE VF-Port 0 VN-Port(s)
210 8 18 02d200 -- 10G Online FCoE VF-Port 0 VN-Port(s)
211 8 19 02d300 -- 10G Online FCoE VF-Port 0 VN-Port(s)
212 8 20 02d400 -- 10G Online FCoE VF-Port 0 VN-Port(s)
213 8 21 02d500 -- 10G Online FCoE VF-Port 0 VN-Port(s)
214 8 22 02d600 -- 10G Online FCoE VF-Port 0 VN-Port(s)
215 8 23 02d700 -- 10G Online FCoE VF-Port 0 VN-Port(s)
To display devices logged in to FCoE port 2/0 on the Brocade FCoE10-24:
switch:admin> fcoe --loginshow 2/0
Number of connected devices: 1
============================================================
Peer Type Connect Info Device WWN Device MAC
=============================================================
FCOE_DEVICE Direct 10:00:00:05:1e:8f:fb:12 00:05:1e:8f:fb:12
==========================================================
Session MAC FCoE Port MAC Te port
==========================================================
0e:fc:00:91:40:01 00:05:1e:7b:34:e0 Te 2/0
To display the configuration for FCoE port 2/0 on the Brocade FCoE10-24:
switch:admin> fcoe --cfgshow 2/0
Slot: 2, Port: 0, Status: Enabled, \
Port WWN: 20:40:00:05:1e:92:de:00,
DeviceCount: 1, Type: VF-Port, MAC: 00:05:1e:7b:34:e0
VF_ID: 128, Fabric Name: 10:00:00:05:1e:35:bb:32