portCfgShow
2
Reserved Buffers
Displays the reserved buffers for the port. This field is displayed only when
portCfgShow is executed for a single port and would only display for LS and LD
long distance mode.
Locked L_Port
Displays ON when the port is locked to L_Port only. Displays (..) or OFF when
L_Port lock mode is disabled and the port behaves as a U_Port). This value is set
by the portCfgLport command.
Locked G_Port
Displays ON when the port is locked to G_Port only. Displays (..) or OFF when
G_Port lock mode is disabled and the port behaves as a U_Port. This value is set
by the portCfgGport command.
Disabled E_Port
Displays ON when the port is not allowed to be an E_Port. Displays (..) or OFF
when the port is allowed to function as an E_Port. This value is set by the
portCfgEport command.
ISL R_RDY Mode
Displays ON when ISL R_RDY mode is enabled on the port. Displays (..) or OFF
when ISL R_RDY mode is disabled. This value is set by the portCfgISLMode
command.
RSCN Suppressed
Displays ON when RSCN suppression is enabled on the port. Displays (..) or OFF
when RSCN suppression is disabled. This value is set by the portCfg rscnsupr
command.
Persistent Disable
Displays ON when the port is persistently disabled; otherwise displays (..) or OFF.
This value is set by the portCfgPersistentDisable command.
LOS TOV enable
Displays ON when LOS TOV is enabled on the port; otherwise displays (..) or
OFF. This value is set by the portCfgLossTov command.
NPIV capability
Displays ON when N_Port ID Virtualization (NPIV) is enabled on the port (default).
Displays (..) or OFF when NPIV capability is disabled. This value is set by the
portCfgNPIVPort command.
NPIV PP Limit
Displays the maximum number of allowed logins for the port. Displays the default
of 126 or the configured maximum. This parameter is set with the
portCfgNPIVPort --setloginlimit command.
NPIV FLOGI Logout
Displays ON when the Base Device Logout feature is enabled and the base
device can logout without disrupting the NPIV devices on the same port. Displays
(..) when the base device log out causes the NPIV devices on the same port to log
out.
QOS E_Port
Displays ON when Quality of Service (QoS) is enabled on the E_Port (or EX_Port)
when QoS is enabled in an FCR deployment scenario. Displays (..) or OFF when
QoS is disabled. By default, QoS is enabled if sufficient buffers are available.
Displays AE when QoS is configured as Auto Enabled. In the AE state, QoS is
enabled based on the availability of buffers.
Use islShow to determine the current status of QoS (on or off) in the AE state.
This value is set by the portCfgQos command.