Reference (Supporting Fabric OS v7.3.0) Owner manual

Table Of Contents
Fabric OS Command Reference 915
53-1003131-01
portShow
2
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Enabled (legacy)
QoS Percentages: High 50%, Med 30%, Low 20%
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:52:fe:00
Peer WWN: 10:00:00:05:1e:39:a4:76
Circuit Count: 1
Flags: 0x00000000
FICON: Off
To display a summary view of the FCIP tunnel and circuits showing then legacy flag for the tunnel:
switch:admin> portshow fciptunnel 8/12 -s
-----------------------------------------------------------------------
Tunnel Circuit OpStatus Flags Uptime TxMBps RxMBps ConnCnt CommRt Met/G
-----------------------------------------------------------------------
8/12 - InProg cft--l- 3m3s 0.00 0.00 1 - -
8/12 0 8/xge1 InProg ---4v-s 3m3s 0.00 0.00 1 5000/5000 0/-
8/12 1 8/xge0 InProg ---4-xs 3m0s 0.00 0.00 1 1000/1000 0/-
8/12 2 8/xge1 InProg ---6--s 3m0s 0.00 0.00 1 2000/2000 0/-
-----------------------------------------------------------------------
Flags: tunnel: c=compression m=moderate compression
a=aggressive compression
A=Auto compression f=fastwrite t=Tapepipelining F=FICON
T=TPerf i=IPSec l=IPSec Legacy
Flags: circuit: s=sack v=VLAN Tagged x=crossport 4=IPv4 6=IPv6
To display a summary view of an FCIP tunnel and its circuits on the Brocade FX8-24 with the --perf
option :
switch:admin> portshow fciptunnel 7/12 --summary --perf
----------------------------------------------------------------------
Tunnel Circuit TxMBps RxMBps ComRatio RTT(ms) ReTx OutOfSeq SlowStart
----------------------------------------------------------------------
1/22 - 0.00 0.00 1.00:1 - 0 0 0
1/22 0 1/xge0 0.00 0.00 - 0 0 0 0
1/22 1 1/xge1 0.00 0.00 - 0 0 0 0
----------------------------------------------------------------------
To display a summary view of the QoS configuration on FCIP tunnels and circuits on the Brocade
FX8-24:
switch:admin> portshow fciptunnel 7/12 --summary --qos
-------- ---------------------------------------------------------
Tunnel Circuit Priority Uptime Tx Bps Rx Bps TxPkts/s RxPkts/s
------- ---------------- ----------------- - -----------------------
1/22 - - 2d23h10m 0.00 0.00 0.00 0.00
1/22 - F-Class 2d23h10m 0.00 0.00 0.00 0.00
1/22 - High 2d23h10m 0.00 0.00 0.00 0.00
1/22 - Medium 2d23h10m 0.00 0.00 0.00 0.00
1/22 - Low 2d23h10m 0.00 0.00 0.00 0.00
----- ----------------- ------------------------------------------
switch:admin> portshow fciptunnel 7/12 --summary --qos --circuit
--------------------------------------------------------------------
Tunnel Circuit Priority Uptime Tx Bps Rx Bps TxPkts/s RxPkts/s
--------------------------------------------------------------------
1/22 - - 2d23h11m 0.00 0.00 0.00 0.00
1/22 - F-Class 2d23h11m 0.00 0.00 0.00 0.00