Reference (Supporting Fabric OS v7.3.0) Owner manual

Fabric OS Message Reference 371
53-1003140-01
FCOE-1033
5
Recommended
Action
Wait until the chassis has fully recovered before you perform any operations.
FCOE-1033
Message FIP v1 FLOGI received - VF port in use.
Message Type LOG
Severity INFO
Probable Cause Indicates that a device is trying to log in to a port that already has a device logged in.
Recommended
Action
No action is required.
FCOE-1034
Message Discarded frame received on priority <pkt_ctrlp->pri_in> for which PFC/FCoE is
disabled.
Message Type LOG
Severity WARNING
Probable Cause Indicates that a frame is received on the specified priority, for which priority-based flow control (PFC) or
FCoE is disabled.
Recommended
Action
Change the CEE map assigned to the FCoE map to accommodate the PFC for the specified FCoE
priority or change the FCoE priority using the fabric-map default command under the FCoE
configuration mode.
FCOE-1037
Message Logingroup dropped for switch WWN: <switch WWN>, due to name conflict while
merging.
Message Type LOG
Severity WARNING
Probable Cause Indicates that same login group name exists for two different switches that have different organizationally
unique identifiers (OUIs), but the last three bytes are same.
Recommended
Action
Create the login group for the switch World Wide Name (WWN) with another name that will not lead to a
name conflict.